Note:
the minimum range indicated in the table can vary significantly according to the adjustment of the
single jets (screwed in more or less).
To verify the exact delivery of the fan do tests with clean water.
14.4. HAND LANCES
When using hand lances bear in mind the following notes:
Don’t direct the jet of liquid towards electric power lines or zones where
there is electrical current, houses or where people might pass.
Don’t point the jet at people or animals.
The jet can cause serious injuries simply due to the mechanical force
of the liquid under pressure.
Never block the spraying lever of the lance in an open position because if
the lance falls it will be uncontrollable.
At the end of work after you have stopped the pump, make sure that any
residual pressure in the pipes under pressure has been drained to avoid
unexpected jets when putting the lance away. There are various types of
lances; with a lever, spray gun and pistol grip.
For further information please refer to the handbook in the package.
The lever lance is controlled by opening lever A which, depending on how
much it’s pressed, produces a conical spray or direct jet. The standard
nozzle
is Ø 1.5
The spray gun can produce a direct jet or a conical spray and the type of spray is selected by pushing
lever B forwards or backwards. Use lever C to
open the jet. The standard nozzle is Ø 2.5
Replacement nozzles are available for all of the lances and the capacities are indicated in the tables
TABLES
N° 1.
15.MAINTENANCE
All of the maintenance operations and repairs must be carried out with the
machine and cardan shaft stopped and the tank and circuit clean of any
residues of chemical products.
The maintenance of the atomizer is essential for maintaining a high level of
safety. Also consult the single handbooks of the main components of the
atomizer.
16. PROGRAMMED MAINTENANCE
We recommend using a table of programmed maintenance to follow in time to keep the atomizer in an
efficient working condition.
For major and important maintenance jobs we recommend using the normal AGROSE assistance service
available from your reseller, (if necessary) replacing parts using original spare parts only.
PICTURE 22
Summary of Contents for ATT-1000
Page 1: ...OWNER MANUAL TURBO ATOMIZER MOUNTED TRAILED...
Page 12: ...8 TRAILED TYPE TURBO ATOMIZERS COMPONENTS PICTURE 2...
Page 13: ...9 MOUNTED TYPE TURBO ATOMIZERS COMPONENTS PICTURE 3...
Page 30: ...26 19 ALLOWED FITTINGS TABLE 3A...
Page 31: ...27 ALLOWED FITTINGS TABLE 3B...
Page 34: ...30...
Page 38: ...34...