INSTRUCTIONS FOR USE
AGS 1800 - 2000 EN-HV (HVB)
Rev.9/2018
76
12.6
SPRAYING SECTIONS AND NOZZLES
Figure 12.39
All three types of equipment are equipped with five sections. Spraying sections are arranged across the
equipment so that they enable minimum pressure fall in hoses and best distribution of spraying product
to individual nozzle (Figure 12.39). Installation of hoses is done from diversion valve on pressure
regulator to nozzles. Hoses are connected to diversion valve with quick clamps.
12.6.1
CONNECTION SCHEME
Connection of sections is displayed in Figure 12.39.
Working width
(m)
15
16
18
Number of
sections
5
Number of
nozzles per
section
5 7 6 7 5 6 7 6 7 6 7 8 6 8 7
WARNING: During spraying, use the lowest speed when booms are only opened