INSTRUCTIONS FOR USE
AGS 1800 - 2000 EN-HV (HVB)
Rev.9/2018
106
Figure 15.7
To avoid incorrect connection of hydraulic hoses
of spraying equipment with tractor hydraulics
and improper operation in controlling the
spraying equipment, the hoses are marked with a
label for correct connection:
•
unmarked hose pair: connection to the
hydraulic
cylinder
to
control
the
lifting/lowering of the spray boom
•
hose
pair
with
colour
markings:
connection to the hydraulic solenoid
valve 6/2 EV3 to control the arms and
levelling of the spray boom.
Technical and working characteristics:
Description
Value
Working pressure of safety valve
120 bar – 150 bar
Max. pressure
180 bar
15.5.2.3
CONNECTION TO TRACTOR
Tractor cabin must be fitted with control panel for control of hydraulic cylinders on spraying
equipment. It must be mounted on an appropriate fixed position. K Control panel with supply cable (E
- Figure 15.6), is connected to tractor source of direct electric voltage 12 V DC DC and maximum
current 10A.
The hydraulic hoses are connected to the hydraulic valve on the tractor: the pair with a colour marking
on the hydraulic coupling is connected to a separate line for controlling one lever (simultaneous
opening/closing, levelling, opening/closing of the left arm and opening/closing of the right arm), while
the unmarked pair of hoses is connected to a separate second line for controlling the other lever (spray
boom lifting/lowering) on the tractor.
WARNING: System is not equipped with a safety valve, therefore regard the
allowed working pressure!
WARNING: Do not connect hydraulic hoses to pressure greater than allowed!
WARNING: When connecting hydraulic hoses, tractor hydraulic valves must not
be under pressure!