Problem
Possible cause
Remedy
Page
E-Start Version:
E-starter
- Battery is empty
Charge or replace the battery
32
does not
- Glass fuse is defective
Replace glass fuse
32
start
- Harness, E-starter damaged
Check harness and E-starter
¬
No warning
- Beeper is defective
Replace beeper
signal
- Glass fuse is defective
Replace glass fuse
32
sounds with
- Harness is damaged
Check harness
¬
switched on
- Regulator is defective
Check regulator
¬
ingnition and
when engine
stops
Warning signal - Glass fuse is defective
Replace glass fuse
32
sounds
- Harness is damaged
Check harness
¬
during
- Regulator is defective
Check regulator
¬
operation
- Generator is defective
Check generator
¬
6. Troubleshooting
¬
= For this purpose contact your agria workshop!
6