8.2 Display Symbols
Symbol
Description
0------
Zero is over the setting range
0_______
Zero point is below the setting range
Ad------
Signal to ADC is over maximum range
Ad______
Signal to ADC is below minimum range
--------
Weight is over upper limitation or display data is over limitation
________
Weight is below lower limitation
EEP.E1
CONFIG or CAL parameters are not correctly set
EEP.E2
USER parameter is not correctly set
Lo.bAt
Battery voltage is lower than setting
CAP.- - -
Next displaying content is capacity
CAP.ER
Parameters about Capacity is not correct
CAL.Px
Calibration on point (x)
CAL.OFF
Calibration seal switch is on OFF position
CAL.ON
Calibration seal switch is on ON position
CAL.Er
Calibration error, maybe input data or loaded weight is incorrect, unstable, non-linear
CAL.End
End calibration
OFF
Power OFF the indicator
STB.ER
Unstable time is larger than setting of USER-OTHER-NLD.RNG
AC.xxxx
Accumulation times is xxxx
PR.TARE
Preset TARE weight
COMP
Input COMPARE data mode
HIGH
Input HIGH limitation data of Comparison
LOW
Input LOW limitation data of Comparison
SPL.Lo
Sample load weight of low point.
SPL.HI
Sample load weight of high point.
SPL.PWT
Sample goods weight to calculate piece weight
INP.PCS
Input number of pieces being counted
UNIT.KG
Unit kg is selected
UNIT.LB
Unit lb is selected
PWT.ER
Piece weight error, sample too small (<0.5d)
SPL.PCT
Sample goods weight to calculate
INP.PCT
Input percentage of weighted goods
PCT.ER
Unit percentage weight is too small (<0.5d)