![AGRI TRONIX Brecknell SBI-521 Series Service Manual Download Page 52](http://html1.mh-extra.com/html/agri-tronix/brecknell-sbi-521-series/brecknell-sbi-521-series_service-manual_2869497052.webp)
50
SBI521 Service Manual
HOLD
HLD.MOD
NONE
AUTO
Hold mode
(1)NONE=no hold function
PS.PEAK
(2)PS.PEAK=Positive Peak
number Hold mode. Scale will
display and refresh the positive
peak value from last zero setting.
NG.PEAK
(3)NG.PEAK=Negative PEAK
number Hold mode. It is similar to
PS.PEAK, but a negative number
is used.
TOGGLE
(4)TOGGLE=Press [HOLD] key
to enter HOLD mode. If the
weight is over (NLD.RNG) and
stable, the data will be frozen
until the [HOLD] key is pressed
again to exit.
AVERAG
(5) AVERAG= Average HOLD
mode. In this mode, if the weight
is over (NLD.RNG), and its
variation is less than
(DYN.RNG), the average data in
(AVG.TIM) will be frozen. Press
the [HOLD] key or (HLD.TIM)
time elapsed to exit this mode
AUTO
(6)AUTO=Auto hold mode. It is
similar to AVERAG mode, but if
the one held load is removed,
and a new load that is over
(NLD.RNG) put on scale, the new
load will be automatically frozen.
AVG.TIM
1-60
3
Average data time for HOLD
mode
1-60 seconds
STB.TIM 3*AVG.TI
M - 255
3*
AVG.TIM
Wait time for the scale to be
stable in HOLD mode
3*(AVG.TIM) - 255S
HLD.TIM 0-65535
0
Data HOLD time
0=data will be frozen until HOLD
key pressed.
1-65535=data frozen time is 1-
65535s, after the time elapses,
scale will exit HOLD mode.
HLD.RNG 0 - 255
5
Vibration range of data that can
be averaged and held in HOLD
mode
0=any data can be averaged
1-255= only the data which
vibration is in 1-255d can be
averaged and held.
USER
SubMenu1
SubMenu2
Option
Default
Parameter Description
Comment