SBI521 Service Manual
9
Loadcell Jumper
Set JP3 jumpers for either a 4-wire or 6-wire loadcell.
Table 1.2 Loadcell Jumper Connector(JP3)
1.4.2 RS-232 Serial Port Connections
The SBI-521 indicator comes standard with two full Bi-directional RS-232 serial ports
designed for connection to either a PC or a serial printer.
Connect the serial printer or computer to the RS-232 terminal on the main board.
Communication terminal connections are shown in
. Refer to
and
for COM2 jumpers..
Figure 1.4 RS-232 Connector
Table 1.3 RS-232 Port Connections
Connected Pins
Function
4 wire loadcell is used
6 wire loadcell is used
Designation
Description
Pin
Electrical Level
RX1
port 1 receive
1
-12 to +12 VDC
TX1
port 1 transmit
2
-12 to +12 VDC
GND
ground/common
3
0 VDC
GND
ground/common
4
0 VDC
RX2
port 2 receive
5
-12 to +12 VDC
TX2
port 2 transmit
6
-12 to +12 VDC
1
6
TX2
RX2
GND
GND
TX1
RX1