Troubleshooting
4
2000/3000 X-Series Oscilloscopes Service Guide
93
b
If the VP13V bulk supply was good at the system board
test point, but other supplies coming from the line
filter board were bad at the system board test points,
check them again at the interboard supply connector
J108:
To check the line filter board AC output
When the 13 V bulk power is not being properly supplied,
this procedure tests the AC input to the power supply to
determine whether there is a problem with the line filter
board.
1
Follow the instructions in
“To prepare for internal
assembly troubleshooting”
on page 84.
2
Connect the power cord, and turn on the oscilloscope.
3
Verify that AC power is present at J1 on the power supply
using a DVM and probes as shown in the following picture
(remember this is an AC voltage measurement!).
Test Point
(near J3701)
Expected Value
Assemblies
Supplied
If Good
If Bad
VP5V
+5 V ±3%
Keyboard,
System Board
Go to
“To check the keyboard
supplies”
on page 98.
Replace the line filter board.
VP12V
+12 V ±3%
System Board
If good when the interboard supply
cable is disconnected from the
system board, but bad when the
interboard supply cable is
connected, this indicates a
problem with either the cable or
the assemblies supplied,
1 First, test the interboard supply
cable for opens or shorts using
the DMM.
2 If the interboard supply cable is
good, replace the system board.
Replace the line filter board.
VP1V8
+1.8 V ±3%
System Board
Replace the line filter board.
VP1V4
+1.4 V ±3%
System Board
Replace the line filter board.
VP1V
+1 V ±3%
System Board
Replace the line filter board.
VP1V2
+1.2 V ±3%
System Board
Replace the line filter board.
VP2V5
+2.5 V ±3%
System Board
Replace the line filter board.
VP3V3
+3.3 V ±3%
LCD, System
Board
Go to
“To check the display
supplies”
on page 97.
Replace the line filter board.
Summary of Contents for 2000 X
Page 1: ...s1 Agilent InfiniiVision 2000 3000 X Series Oscilloscopes Service Guide ...
Page 12: ...12 2000 3000 X Series Oscilloscopes Service Guide Figures ...
Page 14: ...14 2000 3000 X Series Oscilloscopes Service Guide Tables ...
Page 22: ...22 2000 3000 X Series Oscilloscopes Service Guide 1 Characteristics and Specifications ...
Page 144: ...144 2000 3000 X Series Oscilloscopes Service Guide 5 Replacing Assemblies ...
Page 156: ...156 2000 3000 X Series Oscilloscopes Service Guide 6 Replaceable Parts ...
Page 160: ...160 2000 3000 X Series Oscilloscopes Service Guide Safety Notices ...