6287 ALLY PLUS User’s Manual
Page 3-26
69 — Specify SCS transparency terminator
This option applies only to SCS data streams. When the two-trigger pseudo
transparency mode is selected (see Option #62), the user normally
terminates pseudo transparency with an invalid character. When this option
is set to 00, any invalid character will terminate pseudo transparency,
including a system NL command. A non-zero value selects a specific
terminator character, and it tells the ALLY PLUS to throw away all other
invalid characters, and to combine only valid pairs for outputting until the
specific terminator is detected.
!ALLY!69=00;
terminate on any invalid character (default)
!ALLY!69=4A;
terminate only on SCS cent sign (¢)