background image

1 - 9

Internal S0 port (AS 32) ¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢

You may connect up to eight ISDN terminals
to one internal S0 access of the telephone
system.
ISDN terminals:
- AGFEO system telephones digital
- ISDN telephones
- ISDN cards
- ISDN fax machines

Depending on current consumption, you
may connect at least four ISDN terminals
that do not have a power supply of their
own.
Example: 4 ISDN telephones or 2 system
telephones digital and 2 ISDN telephones.

The ISDN terminals must operate in accord-
ance with the DSS1 protocol.

In case you want to connect several ISDN
terminals to the internal S0 plug, you have
to install an S0 bus with several sockets.
You connect this bus via a 4 wire srew clip.
You need the following material to install an
internal S0 port:
- Telecommunications cable; we recom-

mend the cable type I-Y (St) Y 2 x 2 x 0.6

- IAE or UAE connection sockets; up to 12

sockets

- Terminators, 100 Ohm, load carrying ca-

pacity 0.25 watt, 2 terminators

An internal S0 bus may be 130 m long (dis-
tance from the telephone to the last IAE /
UAE socket).

You have to terminate the internal S0 bus.
Add two 100 Ohm terminators to the last
IAE/UAE connection socket (drawing 4).

Drawing 4:
Wiring an internal S0 port

Wire pair 1

red
b1 black

Wire pair 2

a2 white
b2 yellow

Pay attention dur-
ing installation to
the enumeration of
the UAE sockets.

Do not confuse a2
with b2 or a1 with
b1 !

100 

Wire pair 1: a1, b1
Wire pair 2: a2, b2

b1

b2

a1

a2

S

0

- internal

100 

Max. distance

130 m S

0

-bus

1

UAE

2 3 4 5

6

7 8

1

UAE

2 3 4 5 6 7 8

1

UAE

2 3 4 5 6 7 8

1

UAE

2 3 4 5 6

7

8

b1

b2

a1

a2

S

0

- internal

100 

100 

IAE

1a 1b

2a 2b

IAE

1a 1b

2a 2b

IAE

1a 1b

2a 2b

IAE

1a 1b

2a 2b

Summary of Contents for AS 31 ST

Page 1: ...1 1 Installation Business Line AS 31 ST AS 32...

Page 2: ...ust be electrically earthed Therefore connect the Euro PE contact plug of the power cable only to an expertly installed socket PE socket to prevent danger to persons and material Before connecting the...

Page 3: ...ith the connection side pointing downwards on a firm and flat surface Minimum distance between the housing and other limits above or below it 50 mm The distance between the telephone sys tem and the 2...

Page 4: ...Caution Disconnect power cord before remove M M Cover latching Cover Cover latching M Swiches S400 and S401 RS 232C Schnittstelle b7 a7 b8 a8 NF U TFE S0 Anschlu extern BE X16 externe MoH X15 X2 X3 X...

Page 5: ...ting a connecting lead 1 Remove the telephone system s 230 V mains plug from the socket 2 Remove the Western plugs of all ex ternal ISDN basic accesses from the telephone system the network termina to...

Page 6: ...1 b1 Internal S0 only AS 32 GND GND 1 2 3 4 5 6 TAE 6 F a b d a d b Systemtelephone Ports 1 to 4 Port 8 230 V Connections of TAE S400 S401 TS TS NF KT T0 T0 Port 3 GND Bell buttom Door hands free unit...

Page 7: ...which must belong to one connecting line must be closed for the point to point connection Point to multipoint connection The point to multipoint connection may consist of an S0 bus Up to 12 ISDN socke...

Page 8: ...ires to the La and Lb wires speech wires of the Vario ports You must not connect the Da and Db connections System telephones Connect system telephones by four wires to the Vario ports by connecting th...

Page 9: ...an internal S0 port Telecommunications cable we recom mend the cable type I Y St Y 2 x 2 x 0 6 IAE or UAE connection sockets up to 12 sockets Terminators 100 Ohm load carrying ca pacity 0 25 watt 2 te...

Page 10: ...ty 30 VDC 1 A or 123 VAC 0 5 A You can only activate the door opener from a terminal of the telephone system after connecting an external bell trans former For connection carry out the following op er...

Page 11: ...ne system drawing 2 Set the volume of external music on hold on the audio device To set or check the vol Connecting external music on hold MoH ume call an internal user of the telephone system from an...

Page 12: ...l ephone system s RS 232C interface to print out connection records For connection you need a cable that corresponds to the pin as signments given below maximum length 3 m Your printer must be set as...

Page 13: ...an a b terminal with DTMF after installation The telephone system recognises the dial ling method in this way If you switch the dialling method on an a b terminal from DTMF to pulse dialling dial a d...

Page 14: ...ne number entered Number of calls 5 Don t disturb off for all terminals Knocking protection off for terminals Transfer of phone numbers to the called party and the caller on Music on Hold MoH internal...

Page 15: ...ection System telephones 4 wire plug in screw terminal a b terminals 2 wire plug in screw terminal Range System telephones 2 x 75 Ohm 0 6 mm twisted 1200 m a b terminals 2 x 50 Ohm 0 6 mm 800 m Dialli...

Page 16: ...ions equipment 73 23 EWG Low voltage devices 89 336 EWG Electromagnetic compatibility This is why your telephone system bears the CE mark AGFEO GmbH Co KG Gaswerkstr 8 D 33647 Bielefeld Internet http...

Reviews: