background image

1 - 10

b7

a7

b8

a8

X2

X5

Port

7

Port

8

TFE 1

TFE 2

TS 1

TS 2

600 Ohm/0,5 W

Telephone
system

Audio module

or

loudspeaker system

In the example, port 8 has the
terminal type "Audio module"

R11
R12
R21
R22

Connecting a door hands free unit (TFE) ¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢

TFE 

- interface conforming to the 4-wire TFE

specification FTZ 123 D12 for the connec-
tion of door stations with amplifiers.

Connections: (drawing 2)
- Connection of a potential-free bell

pushbutton to the contacts KT and +24 V.
The telephone system supports one bell
pushbutton.

- Connection of the DC-free speech circuit

of the TFE to a loudspeaker system or an
audio module AM 20 to the contacts NF
and GND.

- Control of the TFE, of the loudspeaker

system (activation of the amplifier or
power supply) or of the audio module AM
20 (voice/music changeover) via the po-
tential-free relay contacts TS (R4)
Maximum contact load-carrying capacity:
30 VDC/1 A or 123 VAC/0.5 A.

- Control of the door opener via the poten-

tial-free relay contacts T0 (R3)

Maximum contact load-carrying capacity:
30 VDC/1 A or 123 VAC/0.5 A.
You can only activate the door opener
from a terminal of the telephone system
after connecting an external bell trans-
former.

For connection, carry out the following op-
erations:
- Place the connecting leads through the

housing openings.

- Fit the screw terminals onto the connect-

ing leads.

- Insert the screw terminals of the individual

leads onto the provided slots (see draw-
ings 2).

- If you route a connecting lead of the

telephone system outside of the building,
you are advised to use external lightning
protection.
Maximum contact load: 30 VDC/1 A or
125 VAC/0.5 A, ohmic load.

Connecting an audio module or loudspeaker system ¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢

You can connect an audio module or a
loudspeaker system in place of a door hands
free unit or to one of the eight ports for
analog terminals (drawing 5).

The port used to connect the audio module
must be programmed to terminal type "Au-
dio module". With the programming the re-

lay R2 is automatically assigned to the audio
module (TS 1 - TS 2). The relay controls the
speech/music switching of the audio module
for an announcement.

You must connect a resistor 600 ohms/0.5
W to the a/b connections of the "Audio
module" ports.

Drawing 5: Connecting
an audio module

Summary of Contents for AS 31 ST

Page 1: ...1 1 Installation Business Line AS 31 ST AS 32...

Page 2: ...ust be electrically earthed Therefore connect the Euro PE contact plug of the power cable only to an expertly installed socket PE socket to prevent danger to persons and material Before connecting the...

Page 3: ...ith the connection side pointing downwards on a firm and flat surface Minimum distance between the housing and other limits above or below it 50 mm The distance between the telephone sys tem and the 2...

Page 4: ...Caution Disconnect power cord before remove M M Cover latching Cover Cover latching M Swiches S400 and S401 RS 232C Schnittstelle b7 a7 b8 a8 NF U TFE S0 Anschlu extern BE X16 externe MoH X15 X2 X3 X...

Page 5: ...ting a connecting lead 1 Remove the telephone system s 230 V mains plug from the socket 2 Remove the Western plugs of all ex ternal ISDN basic accesses from the telephone system the network termina to...

Page 6: ...1 b1 Internal S0 only AS 32 GND GND 1 2 3 4 5 6 TAE 6 F a b d a d b Systemtelephone Ports 1 to 4 Port 8 230 V Connections of TAE S400 S401 TS TS NF KT T0 T0 Port 3 GND Bell buttom Door hands free unit...

Page 7: ...which must belong to one connecting line must be closed for the point to point connection Point to multipoint connection The point to multipoint connection may consist of an S0 bus Up to 12 ISDN socke...

Page 8: ...ires to the La and Lb wires speech wires of the Vario ports You must not connect the Da and Db connections System telephones Connect system telephones by four wires to the Vario ports by connecting th...

Page 9: ...an internal S0 port Telecommunications cable we recom mend the cable type I Y St Y 2 x 2 x 0 6 IAE or UAE connection sockets up to 12 sockets Terminators 100 Ohm load carrying ca pacity 0 25 watt 2 te...

Page 10: ...ty 30 VDC 1 A or 123 VAC 0 5 A You can only activate the door opener from a terminal of the telephone system after connecting an external bell trans former For connection carry out the following op er...

Page 11: ...ne system drawing 2 Set the volume of external music on hold on the audio device To set or check the vol Connecting external music on hold MoH ume call an internal user of the telephone system from an...

Page 12: ...l ephone system s RS 232C interface to print out connection records For connection you need a cable that corresponds to the pin as signments given below maximum length 3 m Your printer must be set as...

Page 13: ...an a b terminal with DTMF after installation The telephone system recognises the dial ling method in this way If you switch the dialling method on an a b terminal from DTMF to pulse dialling dial a d...

Page 14: ...ne number entered Number of calls 5 Don t disturb off for all terminals Knocking protection off for terminals Transfer of phone numbers to the called party and the caller on Music on Hold MoH internal...

Page 15: ...ection System telephones 4 wire plug in screw terminal a b terminals 2 wire plug in screw terminal Range System telephones 2 x 75 Ohm 0 6 mm twisted 1200 m a b terminals 2 x 50 Ohm 0 6 mm 800 m Dialli...

Page 16: ...ions equipment 73 23 EWG Low voltage devices 89 336 EWG Electromagnetic compatibility This is why your telephone system bears the CE mark AGFEO GmbH Co KG Gaswerkstr 8 D 33647 Bielefeld Internet http...

Reviews: