Safety notes

internal S0 bus.

Connected door hands free units must
conform to the respective interface
definition.

Any other use of the telephone system is
not in accordance with its intended purpose
and is therefore not permitted.

The telephone system has a general
connection permit (Germany: AAE).

The telephone system is intended for
connection to an ISDN basic access (DSS 1).

You may connect all analog terminals to the
analog user ports of the telephone system
that you are also permitted to operate on
the analog telecommunications network.

You may connect all DSS 1 ISDN terminals
to an internal S0 bus (AS 32) that you are
also allowed to operate directly on the ISDN
network. Two digital AGFEO system
telephones can be also connected to every

Safety notes ¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢

!

-- The telephone system conforms

to the prescribed conformity
and safety regulations.

- Attention! The telephone

system must be electrically
earthed. Therefore connect the
Euro PE contact plug of the
power cable only to an expertly
installed socket (PE socket) to
prevent danger to persons and
material.

- Before connecting the

subscriber lines to the
subscribers and the ISDN
network, pull out the 230 V
mains plug to switch off the
telephone system. Mortal
danger!

- Protective measure! Touch the

metal shield of the PC/printer
socket of the telephone system
briely with your finger. This will
discharge any possible
electrostatic charges, thus

protecting the telephone
system’s electrostatically sensiti-
ve components.

- You must not connect and

disconnect subscriber lines
during a thunderstorm.

- Lay subscriber lines in such a

way that no-one can step on
them or stumble over them.

- Prevent the ingress of liquid into

the telephone system as
otherwise short-circuits may
occur.

- No liability can be assumed for

consequential damages such as
the cost of an unintentionally
continued connection.

- The telephone system is out of

operation whenever power
failures occur. You cannot make
telephone calls in such cases.

Summary of Contents for AS 31 ST

Page 1: ...1 1 Installation Business Line AS 31 ST AS 32...

Page 2: ...ust be electrically earthed Therefore connect the Euro PE contact plug of the power cable only to an expertly installed socket PE socket to prevent danger to persons and material Before connecting the...

Page 3: ...ith the connection side pointing downwards on a firm and flat surface Minimum distance between the housing and other limits above or below it 50 mm The distance between the telephone sys tem and the 2...

Page 4: ...Caution Disconnect power cord before remove M M Cover latching Cover Cover latching M Swiches S400 and S401 RS 232C Schnittstelle b7 a7 b8 a8 NF U TFE S0 Anschlu extern BE X16 externe MoH X15 X2 X3 X...

Page 5: ...ting a connecting lead 1 Remove the telephone system s 230 V mains plug from the socket 2 Remove the Western plugs of all ex ternal ISDN basic accesses from the telephone system the network termina to...

Page 6: ...1 b1 Internal S0 only AS 32 GND GND 1 2 3 4 5 6 TAE 6 F a b d a d b Systemtelephone Ports 1 to 4 Port 8 230 V Connections of TAE S400 S401 TS TS NF KT T0 T0 Port 3 GND Bell buttom Door hands free unit...

Page 7: ...which must belong to one connecting line must be closed for the point to point connection Point to multipoint connection The point to multipoint connection may consist of an S0 bus Up to 12 ISDN socke...

Page 8: ...ires to the La and Lb wires speech wires of the Vario ports You must not connect the Da and Db connections System telephones Connect system telephones by four wires to the Vario ports by connecting th...

Page 9: ...an internal S0 port Telecommunications cable we recom mend the cable type I Y St Y 2 x 2 x 0 6 IAE or UAE connection sockets up to 12 sockets Terminators 100 Ohm load carrying ca pacity 0 25 watt 2 te...

Page 10: ...ty 30 VDC 1 A or 123 VAC 0 5 A You can only activate the door opener from a terminal of the telephone system after connecting an external bell trans former For connection carry out the following op er...

Page 11: ...ne system drawing 2 Set the volume of external music on hold on the audio device To set or check the vol Connecting external music on hold MoH ume call an internal user of the telephone system from an...

Page 12: ...l ephone system s RS 232C interface to print out connection records For connection you need a cable that corresponds to the pin as signments given below maximum length 3 m Your printer must be set as...

Page 13: ...an a b terminal with DTMF after installation The telephone system recognises the dial ling method in this way If you switch the dialling method on an a b terminal from DTMF to pulse dialling dial a d...

Page 14: ...ne number entered Number of calls 5 Don t disturb off for all terminals Knocking protection off for terminals Transfer of phone numbers to the called party and the caller on Music on Hold MoH internal...

Page 15: ...ection System telephones 4 wire plug in screw terminal a b terminals 2 wire plug in screw terminal Range System telephones 2 x 75 Ohm 0 6 mm twisted 1200 m a b terminals 2 x 50 Ohm 0 6 mm 800 m Dialli...

Page 16: ...ions equipment 73 23 EWG Low voltage devices 89 336 EWG Electromagnetic compatibility This is why your telephone system bears the CE mark AGFEO GmbH Co KG Gaswerkstr 8 D 33647 Bielefeld Internet http...

Reviews: