background image

1 - 12

Connecting a printer for printing connection charges ¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢

To print out connection records, the printer
must be on all the time and must be con-
nected to the telephone system. The tel-
ephone system stores at least 500 connec-
tion records and the total connection
charges, even in the event of a power fail-
ure.

Remove the printer cable from the system
when no printer is connected. Close the
housing.

You can connect any printer to the tel-
ephone system’s RS 232C interface to print
out connection records. For connection, you
need a cable that corresponds to the pin as-
signments given below (maximum length 3
m).

Your printer must be set as follows:
- 9600 baud
- 8 bits
- 1 stop bit
- no parity

Closing the housing ¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢

Hook the four top cover tabs into the cover
latch of the bottom housing half.

Press onto the bottom edge of the cover un-
til it engages.

The ventilation slots on the housing must
not be concealed. Make sure that air circula-
tion is not impeded.

Drawing 7: Printer cable pin assignments

2

3

5

7

8

2

3

5

6

7

8

20

telephone system

(9-pole connector)

printer

(25-pole connector)

Summary of Contents for AS 31 ST

Page 1: ...1 1 Installation Business Line AS 31 ST AS 32...

Page 2: ...ust be electrically earthed Therefore connect the Euro PE contact plug of the power cable only to an expertly installed socket PE socket to prevent danger to persons and material Before connecting the...

Page 3: ...ith the connection side pointing downwards on a firm and flat surface Minimum distance between the housing and other limits above or below it 50 mm The distance between the telephone sys tem and the 2...

Page 4: ...Caution Disconnect power cord before remove M M Cover latching Cover Cover latching M Swiches S400 and S401 RS 232C Schnittstelle b7 a7 b8 a8 NF U TFE S0 Anschlu extern BE X16 externe MoH X15 X2 X3 X...

Page 5: ...ting a connecting lead 1 Remove the telephone system s 230 V mains plug from the socket 2 Remove the Western plugs of all ex ternal ISDN basic accesses from the telephone system the network termina to...

Page 6: ...1 b1 Internal S0 only AS 32 GND GND 1 2 3 4 5 6 TAE 6 F a b d a d b Systemtelephone Ports 1 to 4 Port 8 230 V Connections of TAE S400 S401 TS TS NF KT T0 T0 Port 3 GND Bell buttom Door hands free unit...

Page 7: ...which must belong to one connecting line must be closed for the point to point connection Point to multipoint connection The point to multipoint connection may consist of an S0 bus Up to 12 ISDN socke...

Page 8: ...ires to the La and Lb wires speech wires of the Vario ports You must not connect the Da and Db connections System telephones Connect system telephones by four wires to the Vario ports by connecting th...

Page 9: ...an internal S0 port Telecommunications cable we recom mend the cable type I Y St Y 2 x 2 x 0 6 IAE or UAE connection sockets up to 12 sockets Terminators 100 Ohm load carrying ca pacity 0 25 watt 2 te...

Page 10: ...ty 30 VDC 1 A or 123 VAC 0 5 A You can only activate the door opener from a terminal of the telephone system after connecting an external bell trans former For connection carry out the following op er...

Page 11: ...ne system drawing 2 Set the volume of external music on hold on the audio device To set or check the vol Connecting external music on hold MoH ume call an internal user of the telephone system from an...

Page 12: ...l ephone system s RS 232C interface to print out connection records For connection you need a cable that corresponds to the pin as signments given below maximum length 3 m Your printer must be set as...

Page 13: ...an a b terminal with DTMF after installation The telephone system recognises the dial ling method in this way If you switch the dialling method on an a b terminal from DTMF to pulse dialling dial a d...

Page 14: ...ne number entered Number of calls 5 Don t disturb off for all terminals Knocking protection off for terminals Transfer of phone numbers to the called party and the caller on Music on Hold MoH internal...

Page 15: ...ection System telephones 4 wire plug in screw terminal a b terminals 2 wire plug in screw terminal Range System telephones 2 x 75 Ohm 0 6 mm twisted 1200 m a b terminals 2 x 50 Ohm 0 6 mm 800 m Dialli...

Page 16: ...ions equipment 73 23 EWG Low voltage devices 89 336 EWG Electromagnetic compatibility This is why your telephone system bears the CE mark AGFEO GmbH Co KG Gaswerkstr 8 D 33647 Bielefeld Internet http...

Reviews: