Print sizes
Applies to d-lab.2
Minimum:
82 mm x 117 mm (3.25" x 4.6") on 82 mm / 3.25" paper width
Maximum:
305 mm x 457 mm (12" x 18") on 305 mm / 12" paper width
Applies to d-lab.2plus/netlab.2plus
Minimum:
82 mm x 89 mm (3.25" x 3.5") on 82 mm / 3.25" paper width
Maximum:
305 mm x 457 mm (12" x 18") on 305 mm / 12" paper width
Electrical requirements
Connection specifications:
3W+N+PE 220/380V, 230/400V, 240/415V
50/60 Hz
3 x 16 A
3W+PE
200V, 210V, 220V, 230V, 240V
50/60 Hz
3 x 25 A
2W+PE
200V, 210V, 220V, 230V, 240V
50/60 Hz
1 x 32 A
1W+N+PE 200V, 210V, 220V, 230V, 240V
50/60 Hz
1 x 32 A
Film and negative / slide formats
Applies only to d-lab.2/2plus
Film size
Negative / slide formats
110 negatives
Format 110 (color)
135 negatives
Full frame, half frame, panorama (color and B/W)
135 slides
mounted 5x5 cm and reversal film strips, color and black-
and -white
IX240 negatives
Classic, HighVision, Panorama (color and B/W)
120/220
negatives
6x4.5 cm, 6x6 cm, 6x7 cm, 6x8 cm, 6x9 cm
120/220
slides
reversal film strips, color and black-and-white
Noise level
65 dB(A) standby
68 dB(A) printing
Main control
Integrated main computer for the main control of the Minilab
Operating system Windows 2000, at least SP4
Touchscreen monitor (LCD or CRT) as user interface
Optional accessories
Additional table for a larger working area
External label printer for price labels
Film carriers for different negative sizes and slides (only d-lab.2/2plus)
LCD touch-screen monitor
Options for further image processing functions
Space requirements for operation
and service
Right
600 mm
Left
1,100
mm
Front
900 mm
Minimum distance to the wall:
for operation
150 mm
for service
600 mm