Installation Planning
DD+DIS303.03E
Chapter 14 / 36
Classic E.O.S. / Classic E.O.S. CL
Edition 6, Revision 0
(Type 5270 / 100 / 105)
10.4 Functional
data
Process code
HT (60s)
IP (90s)
RP (2min)
EXT (3min)
Feeding speed
160 cm/min
(62.99 in/min)
106 cm/min
(41.73 in/min)
80 cm/min
(31.5 in/min)
52 cm/min
(20.47 in/min)
Processing time in DEV
12.5 sec
18.8 sec
24.9 sec
38.3 sec
Processing time
(film 35 x 35 cm)
Film: end / end
incl. Film
71 sec
82 sec
107 sec
124 sec
142 sec
164 sec
218 sec
253 sec
Films / h (35 x 35 cm)
220 150 110 75
Machine tank volumes
Developer
8.8 l (297.6 fl.oz.)
Fixer 1
10 l (338.18 fl.oz.)
Fixer 2
5.8 l (196.15 fl.oz.)
Water
5.8 l (196.15 fl.oz.)
Developer tank temperature
standard
adjustable between
25 °C (77 °F) - 39 °C (102.2 °F)
38 °C
(100.4 °F)
36 °C
(96.8 °F)
34 °C
(93.2 °F)
34 °C
(93.2 °F)
Fixer 2 tank temperature
34 °C (93.2 °F)
Heating time from
20 °C (68 °F) to
34 °C (93.2 °F)
approx. 20 min
Dryer step setting
13 (Software Version CLLC1107;
older versions: 10 steps)
Standard setting
replenishment cycles
Developer / fixer
0.25 m² (3.88 in²)
Standard setting
Replenishment rate
Developer / fixer
400 ml/m²
Water
30000 ml/m²
Range
Replenishment rate
Developer / fixer
50 – 800 ml/m²
Water
3000 – 30000 ml/m²
Water supply
3000 ml/min (101.45 fl.oz./min)
Adjustment range
for water pressure
min.
max.
2 bar
6 bar
Water conductivity value
min. 3 µS / cm
If the value drops below this threshold reliable level detection
in the water tank can no longer be guaranteed!
Water pH value
6.5 to 8
Silver concentration in the
waste water
< 1
ppm