Installation Planning
DD+DIS303.03E
Chapter 14 / 12
Classic E.O.S. / Classic E.O.S. CL
Edition 6, Revision 0
(Type 5270 / 100 / 105)
7
Daylight / Darkroom Installation
(only Classic E.O.S. Type 5270/100)
Chapter 7 “Daylight / Darkroom Installation” only refers to the Standalone
Version Type 5270/100.
Type 5270/105 has been designed for installation as daylight system.
7.1
Machine in the daylight, film feed in the darkroom,
light seal at the darkroom feed table
7.1.1
Installation at the wall opening
Film feed
Darkroom
Daylight
Film output
(wire chute)
A 60° chamfer must be
provided on the wall
opening.
Wall
Wall base
Light seal
(foam rubber – by the meter)
Order no. CM+0000014259
527214nm.cdr
m
in
. 1
120 (
44.
1)
50
(1.
97)
4
3
6
5
2
1
Figure 7
Dimensions in mm (inch)
Wall
opening:
Wall
Wall base
TYPE 5270/100
Wall opening
50 (1.97)
527014jm.cdr
min. 580 (22.8)
max. 680 (26.8)
max.
1
12
0 (4
4.
1)
3
1
2
Figure 8