Installing Two Units Side-By-Side
When two (2) units are installed together, a 23 1/2 inch
x 12 inch (minimum) divider panel needs to be installed
between the two (2) modules (refer to Illustration) with
self-tapping screws. The divider panel can be made of any
material available, (i.e. 1/32 inch aluminum, 1/8 - 1/4 inch
wood paneling), or you can order Kit # 34747-000 from
the AGA MARVEL Service Department. Locate the divider
panel approximately one (1) inch down from the top of the
cabinet and flush with the back of the cabinet. Drill three
(3) pilot holes approximately 1/2 inch up from the bottom
of divider panel, through panel, and into cabinet. Secure
the panel to the cabinet with three (3) screws using pilot
holes previously drilled.
CORNER INSTALLATION AND INSTALLING TWO UNITS SIDE-BY-SIDE
4
Enclosure must permit refrigerator to be removed for
service.
PANEL READY UNITS:
For corner installations, a mini
-
mum one (1) inch filler must be used as shown above.
ANY UNIT WITH FACE MOUNTED HANDLE:
Filler must
be three (3) inches minimum.
A
Cabinet Outline
1” or
3” Min.
Filler
• Install wood shim to one of the
cabinets before installing cut-out
cavity (not provided).
• After properly installing both
cabinets, drill trim and install pan
head screws (provided).
Drill three (3) holes each side equal
distance apart in vertical section of
aluminum frame and install screws
as shown.
Wood Shim
7/8” x 1” x 68”
7/8”
1”