TROUBLESHOOTING
24
Troubleshooting
If product does not start when plugged in, check the fol
-
lowing:
• Does the light bulb go on when the refrigerator door is
opened? If NOT, check bulb, then...
• -Is the cord from the lower cabinet plugged
into the module?
• -Is the power cord plugged in at the recep
-
tacle?
• -Is the circuit breaker or fuse ”on”? Check
by plugging another electric device into the
outlet.
• If light bulb DID go on when the door was opened...
• -Turn the defrost timer clockwise (might be in
“defrost”) until compressor starts.
• If motor “hums”, but does not start...
• -Check for adequate line voltage at the outlet.
• -The module may have been transported or
stored on its side or upside down, causing
temporary displacement of motor oil. Let rest
24 hours, then plug in again.