Ag Leader Technology

 

DirectCommand Installation

Raven Accu-Flow ISO Kit

 

Page 2 of 15 

February 2015 

PN: 2006375 Rev. B 

Important 
Notices 

You will save time and prevent wrong installation of components 
by closely following these step-by-step instructions.  If you have 
questions, call 

Ag Leader Technology

 at 515-232-5363 ext. 1. 

 

Direction words (LEFT and RIGHT) are commonly used when 
describing an installation procedure. Interpret direction words as if 
standing behind equipment and looking forward. 

 

Signal words 

(CAUTION, IMPORTANT 

and 

NOTE

) are provided 

to draw attention to information that is important for the 
safe/correct installation and operation of this product. 

 

 

CAUTION

 – will alert you to situations that will impact the 

physical safety of you or others. 

 

 

IMPORTANT 

– will alert you to the potential for damage to 

the product or loss of data. 

 

 

NOTE

 – will provide you with additional information to 

simplify a procedure or clarify a process. 

 

  Read all instructions first to familiarize yourself with the 

installation procedures. 

 

  Keep parts list and installation instructions for use as a 

reference after completing installation.

 

 

 

Section 
Contents 

Item Page 

Common Components 

Component and Cable Layout 

Safety Notices 

Installing Liquid Product Control System 

Installing the Accu-Flow Cabling 

Installing the ISO Swath Control Kit (Optional) 

10 

Installing the Implement Switch (Optional) 

12 

Setting Up the Display 

14 

 

 

 

Summary of Contents for 4200140

Page 1: ...Switch 4001507 1 Accu Flow Control Valve Adapter Optional 4001635 1 Cable ISOBUS Breakout Type 1 4002597 008 1 CAN Implement Switch Cable 4002658 1 Liquid Rate Control Module 4002861 1 Local CAN Term...

Page 2: ...safe correct installation and operation of this product CAUTION will alert you to situations that will impact the physical safety of you or others IMPORTANT will alert you to the potential for damage...

Page 3: ...06375 Rev B February 2015 Page 3 of 15 Common Components This section contains illustrations of components common to all DirectCommand installations Their purpose is to ensure proper identification an...

Page 4: ...Ag Leader Technology DirectCommand Installation Raven Accu Flow ISO Kit Page 4 of 15 February 2015 PN 2006375 Rev B Component and Cable Layout...

Page 5: ...r Display DirectCommand components and flow meter from electrical system when welding on equipment or jump starting unit to prevent component damage due to power surges or excessive current IMPORTANT...

Page 6: ...for the Liquid Rate Control Module PN 4002861 Make sure to choose a mounting location that is big enough for Liquid Swath Control Module PN 4002862 if it is needed Mount modules where they will be pr...

Page 7: ...f the ISOBUS Breakout Cable to the 6 pin Metripack receptacle of the Active Terminator Cable Imp PN 4003122 8 Connect the Local CAN Terminating Receptacle PN 4002871 and the Local CAN Terminating Plug...

Page 8: ...ific to the Accu Flow Control Valves with a 4 position ConXall Connection If this DirectCommand system is installed using a control valve that does not have 4 position ConXall Connector go to step 11...

Page 9: ...4 pin Deutsch receptacle of the Auxiliary Valve Harness from Table A above to the mating plug on the Flow Control Channel Cable 8 Tee the gray 2 pin connectors of the Auxiliary Valve Harness into the...

Page 10: ...4003970 6 12 Connect the 2 position molded connector of the adapter cable to the Accu Flow Control Valve 13 Connect the spade terminal with the black wire to the white wire coming from the Accu Flow...

Page 11: ...003949 6 to the gray 12 pin receptacle of the Liquid Swath Control Module PN 4002862 7 Connect the gray 2 pin receptacle on the 12 Boom Section Cable to one of the gray 2 pin plugs of the ISOBUS Imple...

Page 12: ...s kit on an implement that is raised out of the ground when not applying it is recommended to install an optional Implement Switch This will prevent the controller from turning on product flow when th...

Page 13: ...plug the 3 pin Weatherpack Shroud labeled NORMALLY CLOSED on the Implement Switch into the 3 pin Weatherpack Tower of the Implement Switch Extension Cable PN 2000453 X Begin routing the Extension Cab...

Page 14: ...etermines the speed of the servo valve when product control error is less than the Response Threshold setting Decreasing the value will cause the servo valve to run slower Allowable Error Determines t...

Page 15: ...30 gpm Two Valve System STANDARD VALVE Inline Servo 100 24 5 Raven Flow Control Valve 3 4 STANDARD VALVE Inline Servo or Bypass Servo 100 24 1 Raven Flow Control Valve 3 4 FAST VALVE Inline Servo or B...

Reviews: