Installation, assembly and setting
42 – 56
Assembly instructions EN
SE20 - SE30
Date 06.09.2021
Version 2.0
The standard parameters may not meet the requirements of your application.
The parameters depend on the load mass and the mechanical structure of
the system.
First, the drive must be referenced. The options listed below are then available.
Possibility 1: Manual shifting
Move axes manually into position (logic voltage ON, power motors OFF) and
then read values from the controller for transfer to the Pick&Place movement.
Possibility 2: Jog mode
Add or subtract value to the current position.
Can be programmed via relative command. The existing module for absolute
positioning can be converted into a module for relative positioning by
changing a variable.
Possibility 3: Set up with safely reduced speed
Please observe the associated instructions for safely reduced speed.
Type
Max.
speed
[m/s]
Max.
Accel.
[m/s
2
]
Max.
Delay
[m/s
2
]
Std.
Speed
[m/s]
Std.
Accel.
[m/s
2
]
Std.
Delay
[m/s
2]
Max.
Item
[mm]
Max.
Item
[mm]
SE20E-x-50-x
0.84
30
30
0.84
20
20
-
-
SE20E-x-30-x
1.7
20
20
1.7
15
15
-
-
SE30E-x-50-x
0.84
30
30
0.84
20
20
-
-
SE30E-x-30-x
1.7
20
20
1.7
15
15
-
-
6.6.2 Switching distance - reference sensor for electric axes
The reference sensor of the rotational axes is mounted with a feeler gauge at
a distance of 0.1 mm parallel to the switching lug. The positions can be found
in the respective drawings (note the axle types).
Summary of Contents for SE20
Page 53: ...Assembly instructions EN SE20 SE30 Date 06 09 2021 Version 2 0 53 56 ...
Page 54: ...54 56 Assembly instructions EN SE20 SE30 Date 06 09 2021 Version 2 0 ...
Page 55: ...Assembly instructions EN SE20 SE30 Date 06 09 2021 Version 2 0 55 56 ...
Page 56: ...56 56 Assembly instructions EN SE20 SE30 Date 06 09 2021 Version 2 0 ...