CS 16 - CS 20 - OI-vers. 5.3 gb. 20190312
Operating sequence of the intermediate position when returing
Positions
Pressure on
Description
1
P1
P4
Slide rear Catch off
2
P2
P4
Slide moves to the front Catch off
3
P2
P3
Slide front Catch off
4
P1
P3
Slide moves to intermediate position Catch
off
5
P1
Pulse on
Approx. P2
(ca.0.2sec
venting)
Before starting from the intermediate
position,
both air chambers must
absolutely be vented
so that the amply air
chambers are not moved to and the exhaust
air flow control can function. Otherwise
module damage must be expected
6
P4
Catch on
7
P1
P4
Slide returns to home position (slide rear)
Catch on