Albert 2 User Manual
February 2018| ©AEVI International GmbH
PAGE 42/46
Any physical penetration causes the device to switch into the “Non-activated” mode, which takes it
out of service and requires Security Inspection and “Re-activation” by the vendor or an authorized
service provider.
If the device is in the “Tamper State”, the merchant must contact the service desk. The explanation of
the above-mentioned codes is as follows:
Code
Explanation
001
Secure Boot Element failure
002
Secure Boot Element invalid
key
004
Secure Boot Element failure
008
Secure Boot Element MAC
refused
010
Security Element failure
020
Security Element failure
040
Security Element failure
080
Security Element failure
100
Secure Boot Element not
responding
200
Security Element not
responding
0F0
Security Element detects
external tamper event
12.4
Battery warning messages
The device displays a warning message if the battery reaches a low charge level, e.g. according to the
default Android 6.0.1 behaviour.