Press the ON/OFF button to turn the dehumidifier ON and OFF. The dehumidifier remembers 
the last setting and starts in that mode.

MODE

 

Press the MODE button to change between one of 5 operating modes. The mode changes each 
time the button is pressed. An icon will be displayed on the Display Screen showing the current 
mode. 

NOTE:  

See the Display Screen section of this manual for the identification and location of 
the MODE icons.

•  Automatic

 – In Automatic Mode, the fan operates continuously and the dehumidifier 

automatically turns on and off based on a set point (40% to 70% humidity) of your choosing 
(see the “Humidity Set” button).

•  Continuous Dehumidificatio

n – In Continuous Dehumidification Mode, the dehumidifier 

operates continuously and the fan automatically switches to either low speed or high speed 
based on humidity level in the room; low fan speed for humidity lower than 55%; high fan 
speed for humidity higher than 60%. When the humidity is between 55% and 60%, the fan 
speed is based on its previous level.

•  Drying

 – In Drying Mode, both the fan and the dehumidifier operate continuously. The fan 

operates at high speed to maximize the air flow through the unit. Use this mode to extract 
the maximum amount of moisture from the air in the least amount of time.

•  Air Purification

 – In Air Purification Mode, the fan operates continuously and the 

dehumidifier is off. This mode only works with a HEPA filter installed in the dehumidifier. 
The fan speed can be set to either low or high by pressing the HUMIDITY SET button.

•  Ventilation

 – In Ventilation Mode, the fan operates continuously and the dehumidifier is off.  

This mode works with or without a HEPA filter installed in the dehumidifier. The fan speed 
can be set to either low or high by pressing the HUMIDITY SET button.

NIGHT MODE

 

Press the NIGHT Mode button to operate the dehumidifier at its quietest setting. When the 
Night Mode button is pressed, the dehumidifier continues to operate in its current setting 
but the fan speed drops to its lowest level. The dehumidifier stays in this mode until the Night 
mode button is pressed again.

NOTE:  

  This speed is lower the lowest speed that can be achieved through other manual or 

automatic settings.

CLEANING MODE

 

Starting with the dehumidifier off, press and hold the CLEANING Mode button for 3 seconds to 
engage the Cleaning Mode. In this mode, the fan operates on high speed to dry out the inside 
of the dehumidifier, and help remove any potential mold or bacteria buildup, and turns off 
automatically. Use this mode before placing the dehumidifier in storage. To cancel, press the 
Cleaning Mode button for 3 seconds and the unit will go back to its previous operating mode.

LOUVER MODE

 

This mode sets the movement of the Lover for regulated air flow distribution. Press the LOUVER 
Mode button to put the Louver in either:
a)   Continuous sweep mode or
b)   A fixed position

CONTROL BUTTONS:

Summary of Contents for Pure & Dry

Page 1: ...00947 1913_EA 03788 READ AND KEEP THIS MANUAL FOR REFERENCE PURPOSES 2 in 1 Dehumidifier and HEPA Air Purifier...

Page 2: ...lay Panel Icons 8 9 Installing HEPA Activated Carbon Filter 10 Water Removal 11 12 Maintenance 13 14 Replacement Parts 14 Helpful Tips 15 Troubleshooting 16 Technical Data 16 Warranty 17 18 This symbo...

Page 3: ...apors or liquids in the vicinity of this or any other appliance Disconnect the power if strange sounds smells or smoke come from the unit Always disconnect the power before cleaning or maintaining the...

Page 4: ...NT SIDE BACK SIDE Washable Pre Filter Front Panel Control Panel Handle Louver Bucket Lid Water Bucket Float Water Level Window Continuous Drain Hose Outlet Air Purification HEPA Activated Carbon Filte...

Page 5: ...RE icon will light up The LOW TEMPERATURE icon will flash if room temperature falls between 35 F and 58 F The dehumidifier should not be used when the LOW TEMPERATURE icon is flashing In the event of...

Page 6: ...d the dehumidifier is off This mode only works with a HEPA filter installed in the dehumidifier The fan speed can be set to either low or high by pressing the HUMIDITY SET button Ventilation In Ventil...

Page 7: ...m 1 to 24 hours in 1 hour increments Press the AUTOMATIC TIMER and the HUMIDITY SET button simultaneously to change the temperature reading from F to C HUMIDITY SET The HUMIDITY SET button is used to...

Page 8: ...te air flow distribution 6 Ventilation Mode Icon Displayed when the fan is running continuously and the dehumidifier is off 7 Cleaning Mode Icon Displayed when Cleaning Mode is activated operating on...

Page 9: ...ted the display icon will swing back and forth and the frequency is 0 5 seconds When the Louvre Mode has been turned off the middle three lines will not be displayed the running display will be displa...

Page 10: ...ication Mode The filter light will flash indicating that a filter needs to be installed NOTE Depending upon usage and environment we recommend you change the HEPA Activated Carbon Filter each season b...

Page 11: ...veral minutes for residual condensate and fully drain into the bucket WATER REMOVAL WARNING To avoid electric shock disconnect power before removing collected water AUTOMATIC DRAINAGE Water can automa...

Page 12: ...E In order to avoid water leakage please ensure the Drainage Hose is firmly connected and fully inserted before use Pitch Drainage Hose slightly downward for proper water drainage 10CM LENGTH OF DRAIN...

Page 13: ...arbon Filter and replace with a new HEPA Filter Replacement Part 49892 Replace the washable Pre Filter and snap back into place Replace front panel After the HEPA Activated Carbon Filter is replaced p...

Page 14: ...Carefully remove the washable Pre Filter Lightly tap or vacuum the washable Pre Filter to remove loose dirt and dust Rinse the filter under cool running water Dry thoroughly before reinserting and clo...

Page 15: ...midifier is in operation open outside windows and doors only when necessary To reduce noise and vibration dehumidifier should be placed on a solid level surface There must be free space of at least 19...

Page 16: ...ily if room temperature is below 41 F There is no air movement The fan blade is blocked Filter is missing Ensure any exterior blockages are removed If disassembly is required please call customer serv...

Page 17: ...erein if our examination shall disclose any part to be defective in workmanship or material If we in our discretion are unable to repair the product after a reasonable number of attempts we will provi...

Page 18: ...his warranty gives you specific legal rights and you may also have other rights which vary from province to province Some provinces and territories do not allow limitations on warranties or on remedie...

Page 19: ...19...

Page 20: ...residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio...

Reviews: