CAUTION:  Your safety and the safe operation of this dehumidifier are very important to us. 

All safety and operating instructions should be read, adhered to and followed 
before the unit is operated. Incorrect operation may cause harm or damage.

This dehumidifier is for indoor use only!

When using your Pure & Dry dehumidifier, basic precautions should always be observed, 
including the following:

•  The dehumidifier must be directly connected to a grounded 110-120 VAC/60Hz power 

supply outlet.

•  Do not, under any circumstances, cut or remove the ground pin from the power cord.

•  Do not exceed the Amp rating of the power outlet.

•  Do not use an extension cord or power strip. 

•  Do not operate unit if the cord or plug is damaged.

•  Do not modify power plug or cord or use a 3-prong to 2-prong adapter.

•  Do not place dehumidifier near heat sources such as heaters or open fire.

•  For your safety, do not store or use combustible materials, gasoline or other flammable 

vapors or liquids in the vicinity of this or any other appliance. 

•  Disconnect the power if strange sounds, smells or smoke come from the unit.

•  Always disconnect the power before cleaning or maintaining the unit or when not in use. 

•  Never operate this dehumidifier in an area that is likely to accumulate standing water. If this 

condition develops, for your safety, disconnect the power supply before stepping into the 
water. 

•  Never unplug by pulling on the cord. Grasp the plug and pull straight out of the receptacle.

•  Do not repair, disassemble and/or modify the unit by yourself. 

•  There must be free space of at least 12” (30.5cm) between any other object and the 

dehumidifier.

•  This unit is not a toy. Do not permit children or others with limitations to operate unit.

•  Do not rest heavy or hot objects on top of the dehumidifier or immerse in water.

•  Do not use harsh or abrasive-type chemicals to clean the filter or unit.

•  Ensure curtains or other hanging objects are not obstructing air intake and exhaust.

•  To help reduce noise and vibration and ensure proper drainage, dehumidifier should be 

positioned on a firm level surface.

SAFETY WARNINGS AND PRECAUTIONS

!

Summary of Contents for Pure & Dry

Page 1: ...00947 1913_EA 03788 READ AND KEEP THIS MANUAL FOR REFERENCE PURPOSES 2 in 1 Dehumidifier and HEPA Air Purifier...

Page 2: ...lay Panel Icons 8 9 Installing HEPA Activated Carbon Filter 10 Water Removal 11 12 Maintenance 13 14 Replacement Parts 14 Helpful Tips 15 Troubleshooting 16 Technical Data 16 Warranty 17 18 This symbo...

Page 3: ...apors or liquids in the vicinity of this or any other appliance Disconnect the power if strange sounds smells or smoke come from the unit Always disconnect the power before cleaning or maintaining the...

Page 4: ...NT SIDE BACK SIDE Washable Pre Filter Front Panel Control Panel Handle Louver Bucket Lid Water Bucket Float Water Level Window Continuous Drain Hose Outlet Air Purification HEPA Activated Carbon Filte...

Page 5: ...RE icon will light up The LOW TEMPERATURE icon will flash if room temperature falls between 35 F and 58 F The dehumidifier should not be used when the LOW TEMPERATURE icon is flashing In the event of...

Page 6: ...d the dehumidifier is off This mode only works with a HEPA filter installed in the dehumidifier The fan speed can be set to either low or high by pressing the HUMIDITY SET button Ventilation In Ventil...

Page 7: ...m 1 to 24 hours in 1 hour increments Press the AUTOMATIC TIMER and the HUMIDITY SET button simultaneously to change the temperature reading from F to C HUMIDITY SET The HUMIDITY SET button is used to...

Page 8: ...te air flow distribution 6 Ventilation Mode Icon Displayed when the fan is running continuously and the dehumidifier is off 7 Cleaning Mode Icon Displayed when Cleaning Mode is activated operating on...

Page 9: ...ted the display icon will swing back and forth and the frequency is 0 5 seconds When the Louvre Mode has been turned off the middle three lines will not be displayed the running display will be displa...

Page 10: ...ication Mode The filter light will flash indicating that a filter needs to be installed NOTE Depending upon usage and environment we recommend you change the HEPA Activated Carbon Filter each season b...

Page 11: ...veral minutes for residual condensate and fully drain into the bucket WATER REMOVAL WARNING To avoid electric shock disconnect power before removing collected water AUTOMATIC DRAINAGE Water can automa...

Page 12: ...E In order to avoid water leakage please ensure the Drainage Hose is firmly connected and fully inserted before use Pitch Drainage Hose slightly downward for proper water drainage 10CM LENGTH OF DRAIN...

Page 13: ...arbon Filter and replace with a new HEPA Filter Replacement Part 49892 Replace the washable Pre Filter and snap back into place Replace front panel After the HEPA Activated Carbon Filter is replaced p...

Page 14: ...Carefully remove the washable Pre Filter Lightly tap or vacuum the washable Pre Filter to remove loose dirt and dust Rinse the filter under cool running water Dry thoroughly before reinserting and clo...

Page 15: ...midifier is in operation open outside windows and doors only when necessary To reduce noise and vibration dehumidifier should be placed on a solid level surface There must be free space of at least 19...

Page 16: ...ily if room temperature is below 41 F There is no air movement The fan blade is blocked Filter is missing Ensure any exterior blockages are removed If disassembly is required please call customer serv...

Page 17: ...erein if our examination shall disclose any part to be defective in workmanship or material If we in our discretion are unable to repair the product after a reasonable number of attempts we will provi...

Page 18: ...his warranty gives you specific legal rights and you may also have other rights which vary from province to province Some provinces and territories do not allow limitations on warranties or on remedie...

Page 19: ...19...

Page 20: ...residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio...

Reviews: