Chapter 2: Installation and Configuration
XC2 Hardware Manual
2.3.2. Hall-Effect Interface
The Hall-effect switch inputs are recommended for AC brushless motor commutation but not absolutely
required. The Hall-effect inputs accept 5 VDC level signals. Hall states (0,0,0) or (1,1,1) are invalid and will
generate a "Hall Fault" axis fault.
Refer to
for Hall-effect device phasing.
Table 2-15:
Hall-Effect Feedback Pins on the Feedback Connector
Pin #
Description
In/Out/Bi
3
+5V Power
(1)
Output
5
Hall-Effect Sensor B (brushless motors only)
Input
10
Hall-Effect Sensor A (brushless motors only)
Input
11
Hall-Effect Sensor C (brushless motors only)
Input
16
+5V Power
(1)
Output
20
Signal Common
N/A
21
Signal Common
N/A
(1) The maximum combined current output is 500 mA.
Figure 2-18:
Hall-Effect Inputs Schematic (Feedback Connector)
44
www.aerotech.com