17
Aermec IDMKUJ. 0113.5356200_01
DMK
EN
1
"ON/OFF" BUTTON:
Press the "ON/OFF" button to start or stop the dehumidifier.
2
"FILTER" BUTTON:
After 250 hours of humidifier operation the FILTER RESET indicator will light up showing that the filter needs cleaning. Remove
and clean the filter. See the paragraph on cleaning the filter.
3
"+/-" BUTTON:
Press to set the required Relative Humidity (RH) between 80% and 35% in steps of 5%. Press the "-" button until the 35%
level to use the CONTINUOUS operating mode which will be shown by the indicator lighting up. In the CONTINUOUS operat
-
ing mode the dehumidifier work continuously at maximum capacity if connected to the direct drain rubber tube or until the
condensate collection bucket is full.
4
DISPLAY:
The display shows the required Relative Humidity (RH) and it is adjusted with the "+/-" buttons. During normal operation the
display shows the actual Relative Humidity (RH) of the space, with a tolerance of ±
5%.
5
"FAN SPEED" BUTTON:
Press to set the fan speed
HIGH
,
MID
(Medium) or
LOW
. Select a
HIGH
speed for a quicker dehumidification of the air. Once
the required Relative Humidity (RH) is reached set the fan speed to
MID
or
LOW
to have a quieter unit operation.
6
"TIMER" BUTTON:
If the unit is running press the "
TIMER
" button once and the unit will stop after 2 hours, press the button twice and the unit
will stop after 4 hours. If the unit is off (standby) press the "
TIMER
" button once and the unit will start after 2 hours, press the
button twice and the unit will start after 4 hours.
OTHER CHARACTERISTICS:
Indicator BUCKET FULL lit
The lit indicator shows the:
1.
Condensate collection bucket full.
2. Condensate collection bucket missing.
3. Condensate collection bucket not cor-
rectly fitted.
Alarm
If the condensate collection bucket is full
or missing for more than three minutes
and alarm will sound for around 10 sec-
onds to show that it requires emptying
and/or repositioning.
Automatic stopping
The water level sensor stops the dehu-
midifier when the condensate collection
bucket is full or when it has been removed
or when not correctly fitted.
Automatic defrost
When frost forms on the evaporating coil
the compressors automatically stops and
the fan continuous to run until the frost is
completely thawed from the evaporating
coil. Afterwards the compressor will start
and operate normally.
Power supply interruption
In the event there is an interruption of
the power supply the unit will restart au-
tomatically when power is reapplied and
continue running with the same setting as
before the power interruption.
18. CONTROL PANEL
LEGEND:
2 or 4 hour start/stop timer
Fan speed: high, medi-
um, low
Condensate
collection bucket
full
Continuous operation
Dehumidifier
running
Dirty filter
1
2
4
5
6
3
WARNING: WHEN THE CONDENSATE COLLECTION BUCKET IS FULL OR REMOVED NO CONTROLS CAN BE SET.