HM750A1000 Advanced Electrode Steam Humidifier

QUICK INSTALLATION GUIDE

READ AND SAVE THESE INSTRUCTIONS.

This guide should be kept by the installer. Comprehensive information 

and best practices are available in the complete product guide available at 

customer.honeywell.com

INCLUDED IN THE BOX

•  HM750 steam humidifier

•  H6062 HumidiPRO

•  Steam distributor nozzle

•  Rubber drain hose

•  LDPE water hose

•  Baffle (duct mount only)

•  Foam gasket (duct mount only)

•  Steam hose (wall mount only)

•  Fittings, hardware, and mounting 

template

NOTE 

The humidifier comes with a salt tablet inside its cylinder to boost 

conductivity during humidification. The salt tablet may make a rattle noise 

when the humidifier is moved.

TOOLS AND SUPPLIES NEEDED

•  Flat-head screwdriver

•  Phillips screwdriver

•  Wrench

•  Copper pipe (optional)

MOUNTING

Location Requirements

The HM750 can be installed on a 2x4 stud beside the furnace or directly on 

the air supply duct. Keep the following in mind when choosing a location to 

install the humidifier:
•  The humidifier must be level and mounted vertically to 2x4 stud or supply duct. 

Allow minimum clearances shown in Fig. 1.

•  The location must have ambient temperature between 41 and 104 °F 

(5 - 40 °C) and relative humidity of 5-95% (non-condensing).

24 INCHES (610 MM)

4 INCHES (102 MM)

1 INCH
(25 MM) 

41˚ - 104˚ F
(5˚ - 40˚ C)

5-95%

M36860

1 INCH (25 MM) IF WIRED BEFORE MOUNTING.
36 INCHES (914 MM) FOR WIRING ACCESSIBILITY.

1

1

Fig. 1. Recommended clearances.

M36946

AIR FLOW

                         

M36947

AIR FLOW

Fig. 2. Wall mount.                                  Fig. 3. Duct mount.

Mounting to a Wall

The HM750 comes in wall-mount configuration. In this configuration, the 

humidifier can be mounted to a 2x4 stud and the steam distributor nozzle, 

located at the end of a 5 ft. (1.5 m) steam hose, is inserted through the air 

supply duct (see Fig. 2).

NOTE 

Use #8 screws at least 2 in. (5 cm) in length (included) to mount directly to a 

2x4 stud Use longer screws if the stud is behind a drywall or other spacer.
NOTE 

The steam distributor nozzle MUST be installed higher than the humidifier 

(see Fig. 2. The steam hose should maintain an inclination of at least 4 

inches (10 cm) of rise for every 12 inches (30 cm) of run.

1.  Remove the humidifier cover and pull out the cylinder. Insert the top screw 

until 1/4 in. (6 mm) is exposed. Hang the humidifier via its keyhole on the 

screw head (see Fig. 4).

2.  After making sure the humidifier is level, affix it to the stud with another 

screw at the lower stud-mount location (Fig. 4).

M36932

KEYHOLE

STUD
MOUNT

DUCT
MOUNT

DUCT
MOUNT

Fig. 4. Mounting locations (rear view).

3.  Drill a 1-3/4” hole in the duct for the steam distributor nozzle. Attach the steam 

hose to the distributor nozzle and the remote adapter on the humidifier. Then 

insert the steam distributor nozzle and secure it with screws.

33-00288EF-03

Summary of Contents for HM750A1000

Page 1: ...02 MM 1 INCH 25 MM 41 104 F 5 40 C 5 95 M36860 1 INCH 25 MM IF WIRED BEFORE MOUNTING 36 INCHES 914 MM FOR WIRING ACCESSIBILITY 1 1 Fig 1 Recommended clearances M36946 AIR FLOW M36947 AIR FLOW Fig 2 Wall mount Fig 3 Duct mount Mounting to a Wall The HM750 comes in wall mount configuration In this configuration the humidifier can be mounted to a 2x4 stud and the steam distributor nozzle located at t...

Page 2: ...the drain hose supplied to the drain connection Fig 5 The humidifier contains an internal air gap so the drain hose can be connected directly to the red drain spigot using a gear clamp included A condensate pump can be used as the drain water is always tempered MAIN SUPPLY L1 L2 N GND OPTIONAL OFF ON M36861 HOT NEUTRAL GROUND Fig 7 120 VAC 1 Phase Primary power connection ELECTRICAL CONNECTIONS WA...

Page 3: ...IRING FOR FAN INTERLOCK EQUIPMENT OPTIONAL 2 WHEN SHIPPED THE INTERNAL GROUND IS CONNECTED TO THE J13 TERMINAL FOR COMPATIBILITY WITH MOST GFCI AND NON GFCI CONNECTIONS IF THERE ARE ISSUES WITH GFCI MOVE THE GREEN WIRE FROM J13 TO J14 3 J14 J13 Fig 9 Control wiring overview LED INDICATORS Idle The humidifier is on but there is no call to humidify Filling The humidifier is on and has a call to humi...

Page 4: ...l make the determination whether the product should be returned to the following address Honeywell Return Goods Dock 4 MN10 3860 1985 Douglas Dr N Golden Valley MN 55422 or whether a replacement product can be sent to you This warranty does not cover removal or reinstallation costs This warranty shall not apply if it is shown by Honeywell that the defect was caused by damage which occurred while t...

Page 5: ... 104 F 5 95 MF36860 1 PO 25 MM SI L APPAREIL EST CÂBLÉ AVANT LE MONTAGE 36 PO 914 MM POUR PERMETTRE L ACCÈS AU CÂBLAGE 1 1 Fig 1 Dégagements recommandés MF36946 ÉCOULEMENT D AIR MF36947 ÉCOULEMENT D AIR Fig 2 Montage mural Fig 3 Montage sur conduit Montage au mur Le HM750 est préconfiguré pour être fixé au mur Dans cette configuration l humidificateur peut être fixé sur un montant de 2 x 4 et la b...

Page 6: ...nnectez le tuyau de vidange fourni au raccord de vidange Fig 5 L humidificateur comporte un espacement d air à l intérieur Par conséquent il est possible de brancher le tuyau de vidange directement au robinet de vidange rouge à l aide d un collier de serrage à vis sans fin fourni Une pompe à condensat peut être utilisé comme l eau de vidange est toujours temperé MAIN SUPPLY L1 L2 N GND FACULTATIF ...

Page 7: ...FAUT LA MISE À LA TERRE INTERNE EST RELIÉE À LA BORNE J13 POUR LA COMPATIBILITÉ AVEC LA PLUPART DES CONNEXIONS AVEC OU SANS DISJONCTEUR DIFFÉRENTIEL S IL Y A DES PROBLÈMES AVEC LE DISJONCTEUR DIFFÉRENTIEL BRANCHER LE FIL VERT À LA BORNE J14 À LA PLACE 3 J14 J13 Fig 9 Cablage des dispositifs VOYANTS DEL Idle En veille L humidificateur est sous tension mais ne produit pas d humidité Filling Rempliss...

Page 8: ...e suivante Honeywell Return Goods Dock 4MN10 3860 1985 Douglas Dr N Golden Valley MN 55422 ou si un produit de remplacement peut vous être expédié La présente garantie ne couvre pas les frais de retrait ou de réinstallation La présente garantie ne s appliquera pas s il est démontré par Honeywell que la défaillance est due à un endommagement du produit qui s est produit lorsque le consommateur l av...

Reviews: