66
SAT MODE
The Time to Desaturate counter provides calculated time for Tissue Desatuation at sea level
taking into consideration the Conservation Factor setting. It begins counting down 10
minutes after surfacing from a dive, counting down from 23:50 max to 0:00 (hr:min).
When the Countdown reaches 0:00, which will generally occur prior to the FLY count-
down reaching 0:00, the SAT screen continues to alternate with FLY displaying 0:00 until
the FLY counter shuts the Elite T3 Off 24 hours after a last dive.
> The SAT screen is not displayed after a Violation Dive.
> Desaturation requiring Times greater than 24 hours will display 23: - - .
> In the event that Time to Desaturate still remains at the end of 24 hours, the added
time will be zeroed.
During the first 2 hours after a dive -
pressing and releasing the A button 4 times momentarily (< 2 seconds each time)
while the NORM SURF MAIN screen is displayed will access SAT MODE (NORM
SURF MAIN > ALT > PLAN > FLY > SAT, or -
the SAT screen is not accessible from GAUG SURF MAIN.
Two hours after a NORM or FREE dive, the SAT screen will alternate with the FLY screen
until the Elite T3 shuts Off 24 hours after the last dive. When operating in FREE Mode, the
SAT screen can be viewed by first accessing the NORM SURF MAIN screen.