SET NORM SAFETY STOP information includes (Fig. 38):
> Graphic SAFE
> Symbols STOP and TIME.
> Safety Stop Time Set Point, flashing.
> Safety Stop Depth Set Point and symbol FT (or M).
Pressing and releasing the S button momentarily (< 2 seconds each) will step through
the Stop Time Set Points of OFF, 3:00, and 5:00 (minutes:seconds).
Pressing and releasing the A button momentarily (< 2 seconds) will save the Stop Time
setting and the Stop Depth Set Point will flash, or if Stop Time is set OFF advance to
the SET CONS (Conservative Factor) screen with the Set Point flashing.
Pressing and releasing the S button momentarily (< 2 seconds each) will step through
the Stop Depth Set Points of 10, 15, and 20 FT (or 3, 4, 5, and 6 M).
Pressing and releasing the A button momentarily (< 2 seconds) will save the Safety
Stop settings and/or advance to the SET CONS screen with the Set Point flashing.
Pressing the A button repeatedly (< 2 seconds) will step through the other SET U
screens.
Depressing the A and S buttons simultaneously for 2 seconds
will save the settings and revert to the SET U screen.
Depressing the M button for 2 seconds or if no button is
pressed for a period of 2 minutes operation will revert to the
NORM or GAUG SURF MAIN screen.
Fig. 38 - Set Safety Stop