49
SET SAMPLING RATE information includes (Fig. 41):
> Graphic SAMP
> Symbol TIME.
> Set Point, flashing.
Pressing and releasing the S button momentarily (< 2
seconds) will step through the Set Points of :02, :15, :30,
:60 (seconds).
Depressing the S button will scroll through the Set Points at
a rate of 4 Set Points per second until it is released.
Pressing and releasing the A button momentarily (< 2
seconds) will save the setting and/or advance to the SET
TMT 1 screen with the Set Point flashing.
Pressing and releasing the A button repeatedly (< 2
seconds each) will step through the other SET U screens.
Depressing the A and S buttons simultaneously for 2
seconds shall save the setting and revert to the SET U
screen.
Depressing the M button for 2 seconds or if no button is
pressed for a period of 2 minutes operation will revert to
the NORM or GAUG SURF MAIN screen.
NOTE: FREE Mode has a separate fixed Sam-
pling Rate of 1 second.
Fig. 41 - Set Sampling Rate
SAMPLING RATE is
the frequency (time
interval) at which
data is sampled and
stored in memory for
subsequent down-
load to the AERIS
Computer Interface
program.