122
FREE DIVE MODE
When FREE (Free Dive Mode) is selected as the Operating
Mode, the Elite T3 will operate as a Digital Depth Gauge with
select features.
Nitrogen loading is calculated based upon a default FO2 of AIR
and the amount remaining during 24 hours is carried over
between FREE and NORM Operating Modes.
FREE Mode Alarms and their Set Points are independent of those
for NORM and GAUG Mode, and they cannot be silenced.
To access FREE Operating Mode while NORM GAUG
MAIN is displayed, depress the M button for 2 seconds.
NORM SURF > GAUG SURF > FREE SURF MAIN
FREE SURF MAIN DISPLAY, information includes (Fig. 104) -
> Graphic FREE alternating with the Altitude Level graphic
SEA (or EL 2 through EL13) or graphic WET (if wet).
> Battery icon if an Elite T3 Low Battery Warning Condition
exists, flashing if Too Low.
> Graphic tot - with symbol DIVE and accumulated Total
number of repetitive FREE Dives conducted in that series.
> Symbols TIME and SURF and Surface Interval Time (min:sec
up to 59:59, then hr:min).
Fig. 104 - FREE SURF MAIN