On pressure reducers equipped with a pressure gauge, pressure can

be seen on the gauge itself.

WARNING:  Some  pressure  regulators  do  not  have  "push  to  lock",

therefore simply turn the knob to adjust the pressure.

MAINTENANCE

Before attempting any maintenance jobs on the compressor, make sure 

of the following: 

– Master power switch in position  “0”.

– Pressure switch and the control unit switches all off, in position “0”. 

– No pressure in the air tank. 

Every 50 hours of duty: we advise you to dismantle the suction filter and 

clean the filtering element by blowing  compressed air on it (fig. 24). 

You are recommended to replace the filter element at least once if the 

compressor operates in a clean environment, but more frequently if in a 

dusty environment. 

In the “red-head” models  (fig. 25) (TR200 – TR255), the suction filter is 

located internally under the conveying cover (read-head). Unscrew the 

three cover securing screws, remove the cover from the guard joint, 

remove the filter from its seat, and begin cleaning, blowing compressed 

air in opposite to normal flow direction. 

In the Silent model, the filtering element can be replaced by taking off

the soundproofing cabinet and proceeding in the same way as for the 

AB models (fig.29A). 

The compressor generates condensate water which accumulates in the 

tank.

The condensate in the tank must be drained at least once a week, by 

opening the drain tap (fig. 26) under the tank. 

Take care if there is compressed air inside the cylinder, and water could 

flow out with considerable force. Recommended pressure: 1 – 2 bar 

max.

Condensate of compressors that are oil lubricated must not be drained 
into the sewer or dispersed in the environment as it contains oil. 

OIL CHANGES – TOPPING UP WITH OIL 

The compressor is filled with synthetic oil “FIAC Oil Synthesis”.

We recommend a full change of oil in the pumping element within the

first 100 hours of duty.

The soundproofing cabinet is to be taken off first in the Silent model

(fig.29A).

Unscrew the oil drain plug on the housing cover, allow all the oil to flow

out, and re-screw the plug (fig. 27 - 28).

Pour oil into the upper hole of the housing cover (fig. 29 - 30) until it

reaches the level indicated on the stick (fig. 9) or indicator (fig. 11)

Pour oil into the upper hole of the head (fig. 30) in belt assisted units

designed for topping up in that area.

For the GM203 series, take the cap off and pour in 85 grams of oil

directly from the bottle (see fig. 30a).

Once a week: check oil level of the pumping element (fig. 11) and see if

it needs topping up.

For operation at ambient temperature in the range -5

°

C to +40

°

C, use

synthetic  oil. The  advantage  of  this  oil  is  that  is  does  not  lose  its

characteristics either in winter or summer.

Do not drain used oil into the sewer or dispose of it in the environment.

OBSERVE THIS TABLE FOR OIL CHANGES 

TYPE OF OIL 

HOURS OF DUTY 

FIAC Oil Synthesis...................................500 

Synthetic oil: 

AGIP Sint 2000 Evolution - BP Visco 5000 - ESSO Ultron -

MOBIL Mobil 1 - NILS Dimension S - NUOVA STILMOIL

Arrow5W50............................................400

Other types of oil: mineral multigrade

SAE 15 W40...........................................100

WHAT TO DO IF SMALL MALFUNCTIONS OCCUR 

Loss of air in valve under pressure switch 

This  trouble  depends  on  poor  tightness  of  the  check  valve  –  take 
the following action (fig. 31): 
– Discharge all pressure from the tank
- Unscrew the hexagon-head of the valve (A)
- Carefully clean both the rubber disk (B) and its seat.
- Refit all parts accurately.

Air losses 

These can be caused by poor tightness of a union – check all unions, 
wetting them with soapy water.

Compressor turns but does not load 

Coaxial compressors: (fig. 32) 
- this may be due to failure of the valves (C1 – C2) or of a seal (B1 – 

B2): replace the damaged part. 
Pulley drive compressors: (fig. 33) 

- this may be due to failure of the valves F1 and F2 or of a seal (D1 – 

D2): replace the damaged part. 

GM 203 compressors: 

This may be due to the breakage of the valves (C1 - C2) or of the 
gasket (B1). Replace the damaged part (fig. 16A). 

- Check if there is too much condensate water inside the tank. 

Compressor no starting 

If the compressor has trouble starting, check the following :
- Does mains power match that of the data-plate? (fig. 14)
- Are power cable extensions of adequate diameter or length?
- Is the work environment too cold? (under 0

°

C)

- For series VX/AB: was the thermal-breaker tripped? (fig. 20); in the

silent series (fig. 21) 

- Is there oil in the housing to ensure lubrication? (fig. 11)
- Is power supplied to the electrical line? (sockets well connected, 

thermal- breaker, fuses in good condition). 

Compressor not stopping 

- If the compressor does not stop when maximum pressure is reached, 

the tank safety valve comes into operation. To repair the valve, contact 
your nearest service centre. 

IMPORTANT

- Do not on any account unscrew any connection while the tank is 

pressurised – always check if the tank is pressure free. 

- Do not drill holes, weld or purposely deform the compressed air tank. 
- Do not do any jobs on the compressor unless you have disconnected 

the power plug. 

- Temperature in operating ambient: 0

°

C +35

°

C.

- Do not aim jets of water or inflammable liquids on the compressor.
- Do not place inflammable objects near the compressor.
- During down-times, turn the pressure switch to position  “0” (OFF). 
- Never aim the air jet at people or animals (fig. 34) 
- Do not transport the compressor while the tank is pressurised. 
- Be careful with regard to some parts of the compressor such as the 

head and delivery tubes, as they can reach high temperatures. Do 
not touch these parts to avoid burns.(fig. 18 - 19) 

- Transport the compressor, lifting or pulling it with the appropriate grips 

or handles (fig. 4 - 6) 

- Keep children and animals well away from the machine operating 

area.

- If using the compressor for painting: 

a) Do not work in closed environments or near to naked flames 
b) Make sure there is adequate exchange of air at the place of work 
c) Protect your nose and mouth with an appropriate mask. (fig. 35) 

- If the electrical cable or plug are damaged, do not use the compressor 

and contact an authorised service centre to replace the faulty element 
with an original spare part. 

Summary of Contents for AC16006

Page 1: ...osalista Air Compressor oil less type Compresseur d air modele sans huile Kompressor Typ lfrei Compressor Olieloos type Luftkompressor oljefritt utf rande Kompressorit ljyt n AC16006 AC19003 AC24020 A...

Page 2: ...NVISNINGOCHUNDERH LLSHANDBOK elektriskakompressorermedsmordakolvar G B F D WARNING Please read understand this manual before operating the compressor AVVERTISSEMENT Vauillez lire attentivement toutes...

Page 3: ...u installerar anv nder eller utf r underh llsarbete p kompressorn I RISCHIO DI SCOSSA ELETTRICA Attenzione prima di effettuare ogni intervento sul compressore obbligatorio disattivare l alimentazione...

Page 4: ...nzione il compressore potrebbe ripartire in caso di black out e successivo ripristino di tensione GB RISKOFACCIDENTALSTART UP Attention the compressor could start automatically in case of a black out...

Page 5: ...5...

Page 6: ...6 14 15 16 17 18 19 20 21 22 23 24 25...

Page 7: ...7...

Page 8: ...8...

Page 9: ...9 GM 203 SILENT AB 1 2 3 4 5 1 2 3 5 4 SILENT VX 1 5 2 3 4...

Page 10: ...10 9 10 11 8 12 1 7 6 5 4 3 2 GM 7 6 5 4 3 2 8 9 10 11 13 14 12 VX...

Page 11: ...SORE COMPRESSOR UNIT GROUPE COMPRESSEUR KOMPRESSORAGGREGAT COMPRESSOR GROEP KOMPRESSORENHED GRUPO COMPRESOR GRUPO COMPRESSOR KOMPRESSORIYKSIKK KOMPRESSORGRUPP 7 FILTRI ARIA AIR FILTER FILTRE AAIR LUFT...

Page 12: ...AF KONDENSVAND DESAG E DEL CONDENSADO PURGA DA CONDENSA O KONDENSSIVEDEN TYHJENNYS KONDENSVATTNETS AVLOPP 11 RUOTA WHEEL ROUE RAD WIEL HJUL RUEDA RODA PY R HJUL 12 VALVOLA DI RITEGNO CHECK VALVE VANNE...

Page 13: ...eep out of reach of children Lock out the storage area 8 KEEP WORK AREA CLEAN Cluttered areas invite injurues Clear all work areas of unnecessary tools debris furniture etc 9 KEEP CHILDREN AWAY Do not...

Page 14: ...re your extension cord is in good condition When using an extension cord be sure to use one heavy enough to carry the current your product will draw An undersized cord willcauseadropinlinevoltageresul...

Page 15: ...led by white indicator light E going on Turn switch B to start the compressor Pos 1 pumping element n 1 only is operating Pos 2 pumping element n 2 only is operating Pos 3bothpumpingelementsareoperati...

Page 16: ...Visco 5000 ESSO Ultron MOBIL Mobil 1 NILS Dimension S NUOVA STILMOIL Arrow5W50 400 Other types of oil mineral multigrade SAE 15 W40 100 WHAT TO DO IF SMALL MALFUNCTIONS OCCUR Loss of air in valve und...

Page 17: ...the compressor is installed HINTS FOR EFFICIENT OPERATION For efficient operation of the machine at full continuing load and at maximum operating pressure make sure the temperature of the work enviro...

Page 18: ...ARCHE ACCIDENTELLE Ne pas transporter le compresseur alors qu il est encore raccord sa source d alimentation ou que le r servoir d air comprim est plein Bien s assurer que le s lecteur de l interrupte...

Page 19: ...r des personnes ou des animaux 29 VIDANGER LE R SERVOIR Vidangerler servoirtouslesjoursoutoutesles4heuresd utilisation Ouvrir le bouchon de vidange et incliner le compresseur pour vider l eau qui s es...

Page 20: ...16A 3 p les terre 5 5 7 5 10 4 5 5 7 5 220 380 3 230 400 3 32A 3 p les terre REMARQUE Les compresseurs mont s sur r servoir de 500 l avec une puissance de CV7 5 55 kW et CV10 7 5 sont disponibles ave...

Page 21: ...te une pression moins lev e Sur les compresseurs dot s d un r ducteur de pression il est n cessaire de r gler correctement la pression de fonctionnement D bloquer le pommeau du r ducteur de pression e...

Page 22: ...est atteinte la vanne de s curit du r servoir entre en fonction Dans ce cas il est n cessaire de contacter le centre de service apr s vente autoris le plus proche pour la r paration ATTENTION Eviter a...

Page 23: ...NNEMENT CORRECT Pour un fonctionnement correct de la machine en pleine charge continue la pression de fonctionnement maximum v rifier que la temp rature dans un local ferm ne d passe pas 25 C Il est c...

Page 24: ...or Arbeiten zur Reparatur Inspektion Wartung Reinigung oder zum Auswechseln von Bauteilen vorgenommen werden 6 VERSEHENTLICHES EINSCHALTEN Den Kompressor nicht transportieren wenn er an die elektrisch...

Page 25: ...des Druckw chters in die Position 0 OFF stellen wenn der Kompressor nicht in Betrieb ist den Kompressor von der elektrischen Speisung abklemmen und den Hahn zum Ablassen der Luft aus dem Kessel ffnen...

Page 26: ...S Die Einphasenkompressoren werden vollst ndig mit Netzkabel und zweipoligem Netzstecker mit Erdungskontakt geliefert Der Kompressor muss an eine geerdete Netzsteckdose angeschlossen werden Abb 12 Die...

Page 27: ...t Steuereinheit befindet der Temperaturschutz sich im Innern der Steuereinheit Wie folgt vorgehen wenn der Temperaturschutz eingreift Abb 22 Die Schalter auf dem Deckel der Steuereinheit in die Positi...

Page 28: ...e VX AB dass der Temperaturschutzschalter nicht eingegriffen hat Abb 20 in der serie silent Abb 21 dass l in der Schutzverkleidung ist um die Schmierung zu gew hrleisten Abb 11 dass das elektrische Ne...

Page 29: ...l CV kW dB A CCS 2 1 5 77 AB245 2 1 5 78 AB 335 3 2 25 80 AB 410 3 2 25 80 AB 510 4 3 85 AB 480 4 3 81 AB 530 4 3 82 AB 550 5 5 4 1 83 AB 671 5 5 4 1 84 AB 851 7 5 5 5 83 AB 1000 10 7 5 88 N TZLICHE R...

Page 30: ...en alvorens eender welk werk inspectie onderhoud schoonmaak vervanging of controle van elk deel uit te voeren 6 ONVOORZIEN OPSTARTEN De compressor niet transporteren terwijl hij verbonden is met de el...

Page 31: ...randwonden te vermijden de buizen de motor en alle andere warme delen niet aanraken 27 DE LUCHTSTRAAL NIET RECHTSTREEKS OP HET LICHAAM RICHTEN Om risico s te vermijden nooit de luchtstraal op personen...

Page 32: ...en fig 13 verwijzend naar de hieronder weergegeven tabel CV kW Voeding volt ph Model stekker 2 3 4 1 5 2 2 3 220 380 3 230 400 3 16A 3 polen aarding 5 5 7 5 10 4 5 5 7 5 220 380 3 230 400 3 32A 3 pole...

Page 33: ...kingsdruktegebruiken meestal zelfs heeft het pneumatische gereedschap minder druk nodig Bij de compressoren voorzien van een drukreductiemachine is het nodig de werkingsdruk goed af te stellen De hend...

Page 34: ...r niet stopt wanneer de maximum druk bereikt wordt treedt de veiligheidsklep van de tank in werking Het is nodig contact op te nemen met de dichtstbijzijnde geautoriseerde assistentiedienst voor de he...

Page 35: ...Voor een goede werking van de machine met een volledige voortdurende lading bij maximum werkingsdruk zich ervan vergewissendatdetemperatuurvandewerkingsomgevingingesloten omgeving niet hoger is dan 25...

Page 36: ...ainoastaan ulkok ytt n KOMPRESSORIN V R NLAINEN K YTT JA HUONOSTI TEHTY tarkoitettuja ja ilmoitettuja jatkos hk johtoja HUOLTO VOIVATAIHEUTTAARUUMIILLISIAVAMMOJA 14 HUOMAA K YTT J LLE T LLAISTEN RISKI...

Page 37: ...FF kompressorin pys ytt miseen 30 ILMAVIRTAPIIRI K yt suositeltuja putkia pneumaattisia ty v lineit jotka kest v t kompressorin maksimity painetta vastaavan tai suuremman paineen VARAOSAT Korjattaessa...

Page 38: ...eelle kun se laskee minimiarvoon Tavallisesti paine ero minimi ja maksimiarvon v lill on noin 2 baaria 29 psi Esimerkki Kompressori pys htyy kun se saavuttaa 8 baarin arvon 116 psi maksimik ytt paine...

Page 39: ...uodatin on koneensis ll johtokuvunalla punap kierr kolmekuvunkiinnitt v ruuvia auki poista se suojuksesta poista suodatin paikaltaan ja puhdista puhaltaen paineilmaa tavallisen suunnan vastaiseen suun...

Page 40: ...i pannaan hyllylle tai lattiaa korkeammalle tasolle se pit kiinnitt toiminnan aikaisen putoamismahdollisuuden est miseksi l pist esineit tai k si suojaristikoiden sis lle tapaturmien ja konevaurioiden...

Page 41: ...45 C Suojaa kompressori suojakankailla pakkauksesta purkamisen j lkeen ennen k ytt nottoa tai tuotantoseisokkien ajaksi jotta sen koneistoihin ei ker nny p ly Jos kompressoria ei k ytet pitk n aikaan...

Page 42: ...MPRESSORN P L MPLIGT VISN r kompressorn inte ska anv ndas b r den f rvaras i en torr lokal d r den r skyddad mot atmosf risk p verkan H ll kompressorn borta fr n barn 8 ARBETSOMR DEH ll arbetsomr det...

Page 43: ...ska du bara anv nda originalreservdelar som r identiska med de delar som ska bytas ut Reparationerna f r bara utf ras i auktoriserade servicecentraler VARNING INSTRUKTIONER F R JORDNING Denna kompress...

Page 44: ...orn till ett jordat uttag fig 12 Trefaskompressorerna L1 L2 L3 PE m ste installeras av en specialiserad tekniker Trefaskompressorerna r inte utrustade med kontakt Koppla den till n tet med en hj lp av...

Page 45: ...siktig om det finns tryckluft inuti flaskan eftersom vattnet kan forsa ut med stor kraft Rekommenderat tryck 1 2 bar max Kondensvattnet fr n en kompressor som smorts med olja f r inte kastas i avloppe...

Page 46: ...10 5 bar Maximalt arbetstryck 10 bar ELEKTRISKA KOMPRESSORER MODELLER AB Maximalt driftstryck 10 5 bar Maximalt arbetstryck 10 bar OBS Kompressorer med tv stadier kan tillhandah llas f r ett bruk til...

Page 47: ...E BEDIENEN STROOMMEETBEVEILIGING 1 2 3 4 5 6 VERBINDINGSKLEMMEN GELEIDERS C CONDENSATOR M MOTOR AU HULPWIKKELING AM WIKKELING VAN DE VERSNELLING DK A FORSYNING P TRYKAFBRYDER T AUTOMATISK OVEROPHEDNIN...

Page 48: ...DEALER S RUBBER STAMP DELIVERY DATE GARANTIE Les lectrocompresseurs sont garantis 12 mois partir de la date d achat document e La pr sente garantie est accord e au client jour avec les paiements Le co...

Page 49: ...uadas Se excluyen siempre de la garant a los motores y otras piezas el ctricas y de desgaste normal GARANTIA Concede se a garantia de 12 meses para os compressores el ctricos a partir da data de venda...

Page 50: ...nlaisessa ymp rist ss Takuuseen eiv t sis lly moottorit ja muut s hk osat ja normaalisti kuluvat osat GARANTI Vi ger en 12 m naders garanti f r elektriska kompressorer med start fr n det dokumenterad...

Page 51: ...52 I GB F D NL E P RU PL SF N S TR CS GR CZ RS...

Page 52: ...ainittu tuote johon t m vakuutus liittyy Marque Trademark Marke Merk M rke AERFAST Type Type Typ Type Typ AC254100 AC16006 AC19003 AC24020 AC25240 AC30419 AC30419 3 PH Matricule Seriennummer Number An...

Page 53: ...f com Austria Heinz B hnen GmbH Co KG Oswald Redlich Strasse 11 A 1210 Wien Phone 43 1 258 21 07 email office heinz buehnen at Belgium Cerclindus NV S A Uilenbaan 120 2160 Wommelgem Phone 32 3 355 03...

Reviews: