19
ErP Directive - regulations 1253/2014 - 1254/2014
a)
Mark
-
AERAULIQA
b)
Model
-
QR590E
c)
SEC class
-
A
B
B
c1)
SEC warm climates
kWh/m2.a
-14,9
-10,8
-7,2
c2)
SEC average climates
kWh/m2.a
-38
-32,9
-28,6
c3)
SEC cold climates
kWh/m2.a
-73,7
-66,9
-61,2
Energy label
-
Yes
d)
Unit typology
-
Residential - bidirectional
e)
Type of drive
-
Variable speed drive
f)
Type of Heat Recovery System
-
Heat recovery
g)
Thermal efficiency of heat recovery
%
71
h)
Maximum flow rate
m3/h
561
i)
Electric power input at maximum flow rate
W
343
j)
Sound power level (L
WA
)
dBA
58
k)
Reference flow rate
m3/h
393
l)
Reference pressure difference
Pa
50
m)
Specific power input (SPI)
W/m3/h
0,344
n1)
Control factor
-
0,65
0,85
1
n2)
Control typology
-
Local
demand control
Central
demand control
Manual
control (no DCV)
o1)
Maximum internal leakage rate
%
0,8
o2)
Maximum external leakage rate
%
0,5
p1)
Internal mixing rate
%
N/A
p2)
External mixing rate
%
N/A
q)
Visual filter warning
-
Visual filter warning on display
r)
Instructions to install regulated grilles
-
N/A
s)
Internet address for pre/disassembly instructions
-
www.aerauliqa.com
t)
Airflow sensitivity to pressure variations
%
N/A
u)
Indoor/outdoor air tightness
m3/h
N/A
v1)
AEC - Annual electricity consumption - warm climates
kWh
1,8
3,1
4,3
v2)
AEC - Annual electricity consumption - average climates
kWh
2,3
3,6
4,8
v3)
AEC - Annual electricity consumption - cold climates
kWh
7,6
8,9
10,1
w1)
AHS - Annual heating saved - warm climates
kWh
19,4
18,6
18
w2)
AHS - Annual heating saved - average climates
kWh
43
41,2
39,8
w3)
AHS - Annual heating saved - cold climates
kWh
84,1
80,5
77,8