Survey of Fault Indications – Display A
Valid for Easy Control units with I/O Variants, Easytronic
+,
not for Easytronic VGA
I/O variants
=
input/output
variants
V
G
A
=
fully integrated dishwasher
P
A
A
=
cycle run display
7 Seg.
=
7-segment
display
A
K
=
acoustic signal
AK*
=
with Easy, when option existing and programmed
Error Indication
Display
7-Segment
Display
PAA - LEDs
Display
Acoustic
number of
squealings
Fault Indication
visible for
customers
Inquiry
Fault Memory
(after-sales
service)
Indication over Reference
Display
Either 7-segment or PAA
possible!
If 7-segment existing, no PAA
output
if existing
depending on
variant
PAA 7-
Seg.
AK PAA 7-
Seg.
AK
A0
prewash
wash
---
!
!
!
!
!
!
A1
prewash
end
---
!
!
!
!
!
!
A2
prewash
drying
---
!
!
!
!
!
!
A3
prewash
drying
end
---
!
!
!
!
!
!
sprayarm
A4
prewash
final rinse
steady sound
when upper sprayarm
positioned
"!
"!
"!
!
LED sprayarm
A5
prewash
final rinse
end
---
!
!
!
!
!
!
over-flow
protection
A6
prewash
final rinse
end
---
!
!
!
"!
"!
!
---
A7
prewash
final rinse
drying
end
---
!
!
!
!
!
!
A8
prewash
intermediate
rinse
---
!
!
!
!
!
!
A9
prewash
intermediate
rinse
end
---
!
!
!
!
!
!
AA
prewash
intermediate
rinse
drying
---
!
!
!
!
!
!
Ab
prewash
intermediate
rinse
drying
end
---
!
!
!
!
!
!
AE
prewash
wash
drying
end
---
!
!
!
!
!
!
Af
prewash
wash
end
---
!
!
!
!
!
!
Short Description
What happens?
if existing
depending on variant
At the cycle start and at the start of any partial cycle,
as well as after door opened/closed resp. power
failure, the sprayarm rotation is checked and
evaluated.
Fault indication until rotational speed of sprayarm is
detected, or there will be no selection.
Max. filling time after filling to level is T
static lev
x 4
(default value = 124 sec)
W hen this time is exceeded, the fault will be detected.
Valve is no longer selected until the next drain phase
(draining to level). Level-dependent filling phases as
well as heating phases are skipped. During that time
there is generally no heating selection.
Summary of Contents for ATAG VA4511AT
Page 1: ...ATAG VA6011LT PT VA4511AT VA5511AT...
Page 19: ...19 10 2001 A B 599 51 21 26 EN Circuit diagram 111 569 200...
Page 20: ...20 10 2001 A B 599 51 21 26 EN Circuit diagram 111 568 900...
Page 21: ...21 10 2001 A B 599 51 21 26 EN Legend...
Page 23: ...23 10 2001 A B 599 51 21 26 EN Circuit diagram 111 527 600...
Page 67: ...AEP Home Products Impact 54 6921 RZ Postbus 249 6920 AE Duiven Nederland...