10.2001 A. B.
599 51 21 26
EN
NTC Temperature Sensor
Pressure Switch
The pressure switch controls the water level.
Without water, contact 11 - 12 is closed.
fN
Switch point with level
65 mm Ws
Reset point with level
45 mm Ws
The pressure switch is not adjustable.
Electronic rotational speed detection for the upper spray-
arm
The rotation speed detection consists of a magnetic sensor
(Hall generator) which is excited/driven ? by a magnet in the
upper sprayarm.
The fault “sprayarm blocked” is indicated when less than 4
revolutions within 40 sec have been detected.
NTC tem perature sensor
temperature/resistance
20 °C / 6032
Ω
25 °C / 4829
Ω
(only w ith fully electronic
30 °C / 3891
Ω
dishw ashers)
40 °C / 2573
Ω
50 °C / 1741
Ω
55 °C / 1444
Ω
60 °C / 1204
Ω
65 °C / 1009
Ω
70 °C / 849
Ω