1
With base removed the circulation pump (1) is accessible.
1
circuit pump
2
turbidity sensor
Removing the base :
-
remove side panels, rear panel and plinth panel
-
gently release base fixing clips with a screwdriver (figure)
-
take off base carefully and release circulation pump,
electronic and heater relay
-
disconnect the float switch