Simple Logger
®
II Series
25
MODEL
CL601
ELECTRICAL
Channels
One
Input
Split CT – AC Current
Input Level
0 to 600A
AC
Accuracy
(50/60Hz)
0 to 5A: Unspecified
5 to 50A: ±(1% of R1A)
50 to 400A: ±(1% of R0.5A)
400 to 600A for duration <10min: ±(3% of R1A)
Resolution
0.1A
Maximum Input Current***
600A < 1 min
Sample Rate
64 samples/cycle
Storage Rate
Programmable from 125ms to 1 per day
Storage Modes
Start/Stop, FIFO and Extended Recording Mode
*
(XRM
™
), Alarm
Recording Length
15 minutes to 8 weeks, programmable using DataView
®
Memory
240,000 measurement (512KB). Recorded data is stored in non-volatile
memory and will be retained even if battery is low or removed.
Communication
USB 2.0 optically isolated
Power Source**
2x1.5V AA (LR6) alkaline batteries
Battery Life
100 hours to >45 days (dependent on sample rate/recording length)
MECHANICAL
Dimensions
9.25 x 4.0 x 1.63
"
(235 x 102 x 41mm)
Weight (with battery)
17.1 oz (485g)
Case
Polycarbonate UL94-V0
Jaw Opening
1 conductor - Ø 1.42
"
(36mm); 2 conductors - Ø 1.00
"
(25mm) each
2 bus bars - 50 x 5mm
Vibration
IEC 68-2-6 (1.5mm 10 to 55Hz)
Shock
IEC 68-2-27 (30G)
Drop
IEC 68-2-32 (1m)
ENVIRONMENTAL
Operating Temperature
14° to 122°F (-10° to 50°C)
Storage Temperature
-4° to 140°F (-20° to 60°C)
Relative Humidity
up to 85% at 95°F (35°C), Non-condensing
Altitude
6562’ (2000m)
SAFETY & ELECTRO-MAGNETIC COMPATIBILITY
Safety Rating
EN 61010-2-032; 300V CAT IV, 600V CAT III; Pollution Degree 2
Protection Degree
IP40
Electro-Magnetic
Compatibility
EN 61326-1; 07/1997 (+A1 10/1998, +A2 09/2001, +A3 05/2004)
CE Approved
Yes
*This unique recording mode provides the opportunity to continuously record over long periods of time
by reducing the storage resolution of the stored data and maintaining matching resolution for the newest
data. Each time the memory fills up using XRM
™
, every other of the oldest stored samples is discarded
making room for newer samples. This process continues until the recording is manually stopped.
**A memory backup capacitor provides backup power while the batteries are being changed. This
backup capacitor will maintain the instrument for up to 10 seconds without batteries installed. After 10
seconds the date and time will need to be reset (data and configuration will be maintained). If the unit is
connected to DataView
®
via a PC, the battery life is 100 hours regardless of the storage rate.
*** Input level beyond this range may damage the instrument.
Specifications are subject to change without notice.