![AEMC Simple Logger II CL601 User Manual Download Page 20](http://html1.mh-extra.com/html/aemc/simple-logger-ii-cl601/simple-logger-ii-cl601_user-manual_2860727020.webp)
Simple Logger
®
II Series
19
MODEL
L432
ELECTRICAL
Channels
Two
Input
One 4-position removable screw-type terminal block
Input Level
(3 ranges/channel)
Range 1:
-100mV to 100mV
DC
Range 2:
-1V to 1V
DC
Range 3:
-10V to 10V
DC
Accuracy
Range 1:
±(0.5% of R1mV)
Range 2:
±(0.5% of R1mV)
Range 3:
±(0.5% of R10mV)
Resolution
Range 1:
0.1mV
Range 2:
1mV
Range 3:
10mV
Maximum Input Voltage***
±
(1.2 x Nominal Range)
Input Impedance
100mV/1V: 80k
W
; 10V: 800k
W
Sample Rate
Maximum of 8 samples taken at storage interval
Storage Rate
Programmable from 125ms to 1 per day
Storage Modes
Start/Stop, FIFO and Extended Recording Mode
*
(XRM
™
), Alarm
Recording Length
15 minutes to 8 weeks, programmable using DataView
®
Memory
240,000 measurement (512KB). Recorded data is stored in non-volatile
memory and retained even if battery is low or removed.
Communication
USB 2.0 optically isolated
Power Source**
2x1.5V AA (LR6) alkaline batteries
Battery Life
100 hours to >45 days
(dependent on storage rate/recording length)
MECHANICAL
Dimensions
5.45 x 2.75 x 1.28" (136 x 70 x 32mm)
Weight (with battery)
6.4 oz (181g)
Case
UL94-V0
Vibration
IEC 68-2-6 (1.5mm, 10 to 55Hz)
Shock
IEC 68-2-27 (30G)
Drop
IEC 68-2-32 (1m)
ENVIRONMENTAL
Operating Temperature
14° to 122°F (-10° to 50°C)
Storage Temperature
-4° to 140°F (-20° to 60°C)
Relative Humidity
Up to 85% at 95°F (35°C), Non-condensing
Altitude
6562’ (2000m)
SAFETY & ELECTRO-MAGNETIC COMPATIBILITY
Safety Rating
EN 61010-1; 50V CAT III; Pollution Degree 2
Protection Degree
IP40
Electro-Magnetic
Compatibility
EN 61326-1; 07/1997 (+A1 10/1998, +A2 09/2001, +A3 05/2004)
CE Approved
Yes