HA-263D (OPERATION)
HA-263
INITIATE A DYNAMIC BATTERY TEST
INITIATE A DYNAMIC TEST OF THE OUTPUT RELAYS
The system tests the back-up battery once every 24 hours. The owner can initiate a dynamic
battery test at any time with the following codes while the system is in diarmed condition.
USER CODE
4
#
Manually initiated testing does not affect the periodic battery test.
The test takes 5 seconds to 2 minutes depending on the condition of the battery.
Manually battery test is usually required after installation of a new back-up battery.
It is necessary to test the output relays periodically to ensure that they work normally. The owner
can key-in the following command to initiate the test while the system is in disarmed condition.
USER CODE
5
#
Both timing and latch output relays operate for 5 seconds to energize the siren and strobe
light.
If the siren or the strobe does not work normally, check the wiring and the device immediately.
Suggest to make test monthly.
The alarm control panel is protected by a built-in tamper switch. Opening of the cabinet will
trigger the tamper switch to give alarm.
The whole system including the tamper switch can be disarmed by setting it into programming
mode with the master code.
MASTER CODE
After the system is in programming mode, the tamper switch is disabled. The cabinet can be
opened for service without triggering an alarm.
Don't forget to press
to set system back to normal operation after service.
!
!
!
!
!
!
!
!
OPEN THE CABINET FOR SERVICE
R
SINCE 1979
8-ZONE ALARM CONTROL PANEL
OWNER'S MANUAL
Installation And Operation
FOR HOME AND OFFICE PROTECTIONS
HA-263K
HA-263D