HA-263D (OPERATION)

HA-263

INITIATE A DYNAMIC BATTERY TEST

INITIATE A DYNAMIC TEST OF THE OUTPUT RELAYS

The system tests the back-up battery once every 24 hours. The owner can initiate a dynamic

battery test at any time with the following codes while the system is in diarmed condition.

USER CODE

4

#

Manually initiated testing does not affect the periodic battery test.
The test takes 5 seconds to 2 minutes depending on the condition of the battery.
Manually battery test is usually required after installation of a new back-up battery.

It is necessary to test the output relays periodically to ensure that they work normally. The owner

can key-in the following command to initiate the test while the system is in disarmed condition.

USER CODE

5

#

Both timing and latch output relays operate for 5 seconds to energize the siren and strobe

light.
If the siren or the strobe does not work normally, check the wiring and the device immediately.
Suggest to make test monthly.

The alarm control panel is protected by a built-in tamper switch. Opening of the cabinet will

trigger the tamper switch to give alarm.
The whole system including the tamper switch can be disarmed by setting it into programming

mode with the master code.

MASTER CODE

After the system is in programming mode, the tamper switch is disabled. The cabinet can be

opened for service without triggering an alarm.
Don't forget to press

to set system back to normal operation after service.

!

!

!

!

!

!

!

!

OPEN THE CABINET FOR SERVICE

R

SINCE 1979

8-ZONE ALARM CONTROL PANEL

OWNER'S MANUAL

Installation And Operation

FOR HOME AND OFFICE PROTECTIONS

HA-263K

HA-263D

Version 01/08

Summary of Contents for HA-263D

Page 1: ...is in disarmed condition USER CODE 5 Both timing and latch output relays operate for 5 seconds to energize the siren and strobe light If the siren or the strobe does not work normally check the wiring...

Page 2: ...way To clear the alarm memory key in USER CODE press then 3 and validate with key USER CODE 3 The zone LEDs with alarm memory are OFF showing that the alarm memory has been cleared The system or the...

Page 3: ...hin the Entry Delay period The system dis arms instantly after Code entry 2 beep confirms correct Code entry 5 beep for wrong code entry Key in the right User Code again after the beeps DISARM THE SYS...

Page 4: ...tection zones in the 3 partitions are as follows Partition 1 ZONE 1 Delay ZONE 2 Instant ZONE 3 Instant Partition 2 ZONE 4 Delay ZONE 5 Instant ZONE 6 Instant Common Partition ZONE 7 Delay Lobby ZONE...

Page 5: ...63 CONNECTION TERMINALS 1 2 AC Power is supplied from a 16 5V AC 1 5Amp minimum transformer at 50 or 60Hz The primary side of the transformer must be connected to an unswitched receptacle a The transf...

Page 6: ...dition The output is equipped with a 2 5A resettable fuse A Satellite Siren Strobe Light unit is a self contained device with built in backup battery which is charged by the hold off voltage from the...

Page 7: ...ck to these terminals and more than one keypads can be allowed The maximum allowed number of keypads and keyswitches are 4 Common ground Clock wire Data wire 12V power common point equipped with a 750...

Page 8: ...n the Standby period NOTE THE HA 263K The standard HA 263K is supplied with only one key switch for arm disarm control of the partition 1 and 2 in combined operation Independent control of the two par...

Page 9: ...itive terminal of the battery and the BLACK wire connects to the negative terminal of the battery The battery should be a 12V sealed lead acid rechargeable type with a capacity of 6 5 7 0Ah The batter...

Page 10: ...HA 263 FEATURE PROGRAMMING PROGRAMMING PREPARATION ACCESS TO PROGRAMMING MODE WITH SYSTEM CODE 8080 In case the Master Code is forgotten The owner requires to apply the following procedures to make s...

Page 11: ...ops the beeps when the alarm period expires if only one of the partitions is armed The system gives warning beeps in both alarm period and after alarm period if both partitions are armed The system st...

Page 12: ...ves 2 short flashes seconds continuously all the time while the system is armed In the condition of there is no alarm occurred when you come back from outside Turn the key switch to make contact until...

Page 13: ...n The System Setting Jumper on the main circuit board MUST be set on DK Position for keypad only or keypad keyswitch operation 1 2 3 4 5 6 7 8 9 10 16 SYSTEM HA 263 13 SUMMARY OF THE VISUAL AND AUDIBL...

Page 14: ...tected by a built in tamper switch Opening of the cabinet will trigger the tamper switch to give alarm If opening of the cabinet for service is required it is necessary to set the system to standby mo...

Reviews: