A Technical Specifications 

User Manual 

 

30

 

 

 

Model 

Index 

6kVA(L) 

10kVA(/B) 

O

th

e

rs

 

Backup time 

For  long  backup  model,  it  can 

be configured any backup time 

according to needs   

For long backup model, it can be 

configured  any  backup  time 

according to needs. 

Charge recovery time 

It is determined by the capacity of external battery pack. 

Communication interface 

RS232 port 

Panel display 

LCD shows the running status of the UPS. 

Alarm function 

Alarm for battery low-voltage, mains abnormal, UPS fault, output 

overload. 

Protection function 

Protect  for  battery  under-voltage,  overload,  short-circuit,  over-

temperature, input over-voltage 

Noise (dB) 

<55 

Work temperature (

-5 ~40 

Relative humidity 

0 ~ 95%, non-condensation 

  Specifications are subject to change without prior notice. 

 

Summary of Contents for IST3-J

Page 1: ...UPS IST3 J 1 10 kVA User Manual...

Page 2: ......

Page 3: ...ters during installation operation and maintenance Safety symbol meaning as follows Symbol Description Alerts you to a high risk hazard that could if not avoided result in serious injury or death Aler...

Page 4: ...ments 3 2 Overview 5 2 1 Product Intro 5 2 1 1 Model Meaning 5 2 1 2 Features 5 2 2 Appearance and Structure 6 2 2 1 appearance 6 2 2 1 Operation Panel 8 2 2 2 Rear Panel 10 2 3 Communication 11 2 4 I...

Page 5: ...intenance 20 4 1 Check Before Startup 20 4 2 Startup Operation 20 4 2 1 1kVA L 2kVA L 3kVA L 20 4 2 2 6kVA L 10kVA B 21 4 3 Shutdown Operation 21 4 3 1 1kVA L 2kVA L 3kVA L 21 4 3 2 6kVA L 10kVA B 21...

Page 6: ......

Page 7: ...er to safety description in the relevant chapters Before using the UPS please read the announcements and operation instructions in this section carefully to avoid accident The promptings in the user m...

Page 8: ...he UPS such as air condition blower starter electric drill motor daylight lamp etc In case of fire use dry powder extinguisher to put out the fire If you use liquid fire extinguisher it may cause elec...

Page 9: ...ter immediately and then see the doctor The waste battery should be disposed according to the local regulations 1 2 Operation and Maintenance Requirements Only authorized professionals are allowed to...

Page 10: ...ibration and the vertical gradient is less than 5 Keep good ventilation around the UPS The clearance between the rear or the side of UPS and adjacent devices or wall should be at least 300mm 500mm Poo...

Page 11: ...l If there is no L symbol it means standard model For the 2 3kVA standard model UPS it also includes a UPS and a battery box For 6kVA L UPS it just has long backup model UPS that the output power is n...

Page 12: ...r power grid and weak shock resistance Low mains input voltage Adopt the independent rapid detection technology When the mains input voltage is 120V which is the lower limit the battery still doesn t...

Page 13: ...e is as shown in Figure2 3 Figure2 3 Battery box appearance of 6kVA L 10kVA B The battery box amount of long backup model is different on the basis of required backup time The relationship between bat...

Page 14: ...oltage UPS temperature output load percentage fault information etc circularly Long press button for 5s the LCD will enter setting page Short press to select the setting command long press button to c...

Page 15: ...ion 1 Running status display area Shows the input output temperature fault type and setting etc of the UPS 2 Output status display area Shows the load capacity battery capacity fault indication and bu...

Page 16: ...andard model is optional Ethernet E C R EPO Output socket UPS 2 3Kva L Communication port Intelligent slot optional Cover SNMP RS485 and dry contact Ethernet E C R USB Mains input socket Battery expan...

Page 17: ...Communication 1kVA L 2kVA L 3kVA L 6kVA L 10kVA B adopt RS232 series port to communicate with PC The corresponding pin relationship of RS232 port between UPS and PC is as shown in Table2 4 Table2 4 Th...

Page 18: ...al is normal close that is PIN1 connects with PIN2 If one route signal needs to set to normal open connect PIN2 with PIN3 2 The requirements for input signal of dry contact the voltage should be less...

Page 19: ...mains is abnormal the battery will boost into the 360V DC voltage for DC AC inverter through DC DC The working principles of the 1 10kVA series UPS is as shown in Figure2 8 Figure2 9 The DC AC invert...

Page 20: ...area of AC input wire AC output wire and battery wire of the UPS please refer to Table3 1 for the corresponding recommended value and choose upwards Table3 1 The recommended cross sectional area of wi...

Page 21: ...er Max curren t Break er Max curren t Break er Max current Break er AC input A 6 10 12 20 18 32 36 50 60 100 DC input for long backup model A 37 50 37 50 42 50 39 50 65 100 3 3 Install UPS The install...

Page 22: ...he battery box is heavy when installing the battery box must be installed down below the UPS 3 4 Intelligent Slot Installation Step 1 Dismantle standard intelligent slot Step 2 Install optional intell...

Page 23: ...perly the electrical connection can be done For standard backup UPS the backup time cannot be expanded for long backup UPS the backup time can be expanded on the basis of needs The DC input voltage of...

Page 24: ...3 Installation User Manual 18 Figure3 3 Wiring diagram of 1kVA L...

Page 25: ...Figure3 5 Wiring diagram of 6kVA L 10kVA B Mains socket should be near by the UPS and easy to operate For long backup model connect the UPS with mains first and then insert the battery expansion wire...

Page 26: ...if the wiring of the RS232 port is correct If it is long backup model check if the wiring between UPS and battery box is correct and reliable Check if the wiring is neat and the wire binding is in acc...

Page 27: ...t loads such as PC etc Start load with the sequence that high power device small power device which is to avoid overload protection when starting high power device 4 3 Shutdown Operation 4 3 1 1kVA L...

Page 28: ...e the working life of battery Charge the battery for 10 hours before using During charging the UPS still can be used but if power outage at the same time the discharging time may be less than the stan...

Page 29: ...ill stop outputting immediately 1 UPS is overload seriously or the output circuit is short circuit Please reduce load to proper capacity or find the short circuit reason The common reason is that the...

Page 30: ...neutral wire and the grounding wire is too high Table4 2 The meaning of fault symbol and buzzer status Fault symbol Buzzer status Meaning Fault info page page up or page down by button EPO Long beep U...

Page 31: ...n closed Load energy bars short circuit light on Long beep Output short circuit the output has been closed Battery energy bar 25 100 over voltage all flicker Slow beep Alarm once about every 2 0s Batt...

Page 32: ...voltage within the range of 120Vac 154Vac the UPS can bear less than 50 load Frequency range Hz 50 60 10 50 60 self adaption Input way Single phase three wire Battery voltage V 24 36 48 72 72 96 Outp...

Page 33: ...With full load for 3min Long backup time Can be configured any backup time according to needs With full load for 3min Long backup time Can be configured any backup time according to needs Charge reco...

Page 34: ...1kVA 1kVA L 2kVA 2kVA L 3kVA 3kVA L Work temperature 5 40 Relative humidity 0 95 non condensation Size W D H mm 438 413 86 UPS weight kg 11 5 8 7 2 8 7 2 8 Battery box weight kg 13 13 17 5 17 5 24 Spe...

Page 35: ...ication Output Capacity VA W 6000 5400 10000 9000 Voltage V 220 2 default can be set to 208 220 230 240 Frequency Hz 50 60 0 2 battery mode Wave form Sine wave Voltage distortion THD 1 linear load THD...

Page 36: ...determined by the capacity of external battery pack Communication interface RS232 port Panel display LCD shows the running status of the UPS Alarm function Alarm for battery low voltage mains abnormal...

Page 37: ......

Reviews: