Advantech SOM-ETX Design Guide
SOM-ETX Modules
Carrier board
SOM-ETX Modules
Carrier board
3mm
The shadow plane must clear to match advantech SOM-ETX design.
3mm
For the special case, we can use 4mm height connector on SOM-ETX
modules.
1mm
Figure 7-2
Connector Hirose FX8-100 Footprint
Figure 7.2 shows the SOM-ETX carrier board connector mechanical dimensions. The
unit is millimeter.
Figure 7-3 SOM-ETX Carrier Board Connector Mechanical Dimensions
Chapter 7 Carrier Board Mechanical Design
119