20
EKI-7712 Series User Manual
2.6
Connecting the Switch to Console Port
The industrial switch supports a secondary means of management. By connecting
the RJ45 to RS232 serial cable between a COM port on your PC (9-pin D-sub
female) and the switch’s RJ45 (RJ45) port, a wired connection for management can
be established.
Figure 2.13 Serial Console Cable
Figure 2.14 DB 9 Pin Position
Figure 2.15 Pin Assignment
DB9 Connector
RJ45 Connector
NC
1 Orange/White
NC
2 Orange
2
3 Green/White
NC
4 Blue
5
5 Blue/White
3
6 Green
NC
7 Brown/White
NC
8 Brown
To terminal or PC
To console port
5
9
1
6
3
6
8
1
7
2
5
4
TXD
RJ45
Male
RXD
NC
NC
NC
NC
GND
GND
2
3
7
8
4
6
5
RXD
DB9
Female
TXD
RTS
CTS
DTR
DSR
GND
Summary of Contents for EKI-7712 Series
Page 1: ...User Manual EKI 7712 Series 8FE 4G 8GE 4G SFP port L2 Managed Switch ...
Page 16: ...Chapter 1 1Product Overview ...
Page 25: ...Chapter 2 2Switch Installation ...
Page 41: ...Chapter 3 3Configuration Utility ...
Page 47: ...Chapter 4 4Managing Switch ...
Page 175: ...Chapter 5 5Troubleshooting ...