138
EKI-7720 Series User Manual
To access this page, click
Diagnostics
>
IPv6 Ping Test
.
Figure 4.210 Diagnostics > IPv6 Ping Test
The following table describes the items in the previous figure.
Item
Description
IPv6 Address
Enter the IP address or host name of the station you want the switch
to ping. The initial value is blank. The IP Address or host name you
enter is not retained across a power cycle. Host names are composed
of series of labels concatenated with dots. Each label must be
between 1 and 63 characters long, and the entire hostname has a
maximum of 64 characters.
Count
Enter the number of echo requests you want to send. The default
value is 4. The value ranges from 1 to 5. The count you enter is not
retained across a power cycle.
Interval (in sec)
Enter the interval between ping packets in seconds. The default value
is 1. The value ranges from 1 to 5. The interval you enter is not
retained across a power cycle.
Size (in bytes)
Enter the size of ping packet. The default value is 56. The value
ranges from 8 to 5120. The size you enter is not retained across a
power cycle.