EKI-7720 Series User Manual
115
4.9
Management
4.9.1
LLDP
LLDP is a one-way protocol without request/response sequences. Information is
advertised by stations implementing the transmit function, and is received and pro
-
cessed by stations implementing the receive function.
4.9.1.1
LLDP System Settings
The LLDP System Settings allows you to configure the status (enabled or disabled)
for the protocol, set the interval for frame transmission, set the hold time multiplier
and the re-initialization delay.
To access this page, click
Management
>
LLDP
>
LLDP System Settings
.
Figure 4.171 Management > LLDP > LLDP System Settings
The following table describes the items in the previous figure.
To access this page, click
Management > LLDP > LLDP System Settings
.
The following figure displays the
LLDP Global Config
settings.
Figure 4.172 Management > LLDP > LLDP System Settings
Item
Description
Enabled
Click
Enabled
or
Disabled
to set the Global Settings state.
LLDP PDU Disable
Action
Click to select the LLDP PDU handling action when LLDP is globally
disabled. Options include: Filtered, Bridged, or Flooded.
Transmission Interval Select the interval at which frames are transmitted. The default is 30
seconds, and the valid range is 5 to 32768 seconds.
Holdtime Multiplier
Select the multiplier on the transmit interval to assign to TTL.
Reinitialization Delay Select the delay length before re-initialization.
Transmit Delay
Select the delay after an LLDP frame is sent.
Apply
Click
Apply
to save the values and update the screen.
Summary of Contents for EKI-7712 Series
Page 1: ...User Manual EKI 7712 Series 8FE 4G 8GE 4G SFP port L2 Managed Switch ...
Page 16: ...Chapter 1 1Product Overview ...
Page 25: ...Chapter 2 2Switch Installation ...
Page 41: ...Chapter 3 3Configuration Utility ...
Page 47: ...Chapter 4 4Managing Switch ...
Page 175: ...Chapter 5 5Troubleshooting ...