APAX-5000 I/O Series User Manual
88
Pulse/DIR, With Reload, Count Once, DI Gate Enable, Low level, Retriggerable
Figure 3.29 shows pulse/direction mode, Ch0_A provides the counting function, one
pulse, one count. Ch0_B provides the clockwise and counter clockwise function.
When the counter0 is enabled, the couner0 starts to count. If the counter value is
overflow or underflow, it will reset to the defined value (e.g. 0x33) and keep counting
repetitively. If the DI0 value is low level, the counter0 will starts to count and can be
retriggered. Otherwise, the counter0 will stop counting.
Figure 3.44 Pulse/DIR, With Reload, Count Once, DI Gate Enable, Low level,
Retriggerable
0x33
0x34
0x35
Up
Down
0x34
0x33
………
0x00
0x33
Ch0_A
Ch0_B
Counter 0
Value
Counter0
Enable
Counter0
Underflow
DI0
0x33
0x32
0x31
Up
Down
0x32
0x33
………
0xF..F
0x33
Ch0_A
Ch0_B
Counter 0
Value
Counter0
Enable
Counter0
Overflow
DI0
Summary of Contents for APAX-5013
Page 1: ...User Manual APAX 5000 Series I O Modules...
Page 8: ...APAX 5000 I O Series User Manual viii...
Page 9: ...Chapter 1 1 Overview...
Page 23: ...15 APAX 5000 I O Series User Manual Chapter 1 Overview...
Page 33: ...Chapter 2 2 Analog Input Output Modules...
Page 49: ...Chapter 3 3 Digital Input Output Modules...
Page 116: ...APAX 5000 I O Series User Manual 108...
Page 117: ...Chapter 4 4 Backplane Modules...
Page 120: ...APAX 5000 I O Series User Manual 112...
Page 121: ...Chapter 5 5 Power Supply Modules...
Page 124: ...APAX 5000 I O Series User Manual 116...