background image

 

Doc No. FM0713 Issue C Page 1 

Entel Ultra  

Door Entry System  

 

____________________________________________________________________________________________________ 

 

 

 

 

  Installation Guide 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

Tynetec operates a policy of continual product improvement and 

reserves the right to modify the specification of its products. 

  

If any variation to the details in this document are suspected please 

contact Tynetec’s Technical Support on 01670 352371.

 

 

 

 

 

 

 

 

 

 

Tynetec, a business unit of Legrand Electric Ltd 

Unit 10 Cowley Road, Blyth Riverside Business Park, Blyth 

Northumberland, NE24 5TF. Tel: 

01670 352 371 

Fax: 

01670 362 807

 

Email: 

[email protected]

 Web: 

www.tynetec.co.uk

 

Summary of Contents for Entel Ultra

Page 1: ...roduct improvement and reserves the right to modify the specification of its products If any variation to the details in this document are suspected please contact Tynetec s Technical Support on 01670...

Page 2: ...es 7 5 Distribution Nodes 10 6 Door Panels 13 7 Camera Panel 16 8 Telephones 17 9 Video Phones 19 10 BT DECT Telephone Interface 21 11 Video Amplifiers Switchers 22 12 Lock Release 24 13 Door Contacts...

Page 3: ...s this also includes a trade timeclock and a low voltage power supply housed in an IP65 lockable steel enclosure The 8 port distribution nodes are available in IP65 ABS or lockable steel enclosures th...

Page 4: ...sed for the video connection between the node and phone If existing cabling is being utilised then check sufficient cores are available If a PAC reader is fitted in the door panel then an additional 6...

Page 5: ...onnected to both Distribution Nodes Telephones connected to both Distribution Nodes 2 MULTIPLE SPEECH PATHS OPTION 1 DIGITAL On multi entrance systems multiple speech paths can be achieved by fitting...

Page 6: ...Distribution Nodes Ground Floor 3 MULTIPLE SPEECH PATHS OPTION 2 DECK ACCESS To help speed the passage of visitors through large deck access systems the floor level functional panels can be connected...

Page 7: ...p with the door hinged on the left hand side The door can be swapped to hinge from the right or the back plate can be inverted if the cable entry plate is required on the bottom Always ensure propriet...

Page 8: ...y The battery is protected by a 20mm 4A quick blow fuse located on the battery protection board 4 07 SYSTEM POWER REQUIREMENTS To ensure the Entel Ultra System Node PSU has sufficient capacity the tot...

Page 9: ...of 0 5mm cable 10 ohms then the drop would be 5V By using 1 pair of wires the resistance will be halved to 5 ohms therefore the volts drop will be halved to 2 5V Always ensure there is a minimum 10 0...

Page 10: ...rd has an 8 way DIL switch for setting a unique ID Distribution board ID s are set in Binary see table below DIL SWITCH No 1 2 3 4 5 6 7 8 BINARY CODE 1 2 4 8 16 32 64 128 Distribution board ID s shou...

Page 11: ...in to switch on off with increasing speed for several minutes Remember to set the correct Board ID and press RESET again when the cleaning cycle is complete 5 06 TELEPHONE SYSTEMS Up to 8 flats can be...

Page 12: ...nes and ZVT455 video phones This Link may be moved to A if alternative manufacturer s telephones are being used that require a switched 0V for the door open LED 5 11 TELEPHONE DISTRIBUTION BUS WIRING...

Page 13: ...elephone is turned off a not available tone is sounded When the door lock is released a distinct pulsed tone is sounded to indicate the door is open 6 01 DOOR PANEL RANGE 6 02 PAC READER OPTION All do...

Page 14: ...x for cable entry this may allow water to enter and damage the electronic components or keypad Cable entry into the backbox should be through the side or rear 20mm knockouts provided IMPORTANT the bac...

Page 15: ...ti entrance systems set DIL switch 1 ON on one door panel only it doesn t matter which one DIL switch 2 should always be OFF 6 09 VOLUME ADJUSTMENT The door panel loudspeaker and telephone earpiece au...

Page 16: ...be clarified with the Supervising Officer The backbox should be cut into the brick work or door screen and sealed with suitable mastic to prevent water ingress 7 03 SURFACE FLUSH COWLINGS If it is not...

Page 17: ...in one of two modes Timed Privacy privacy mode will turn off automatically after a pre set time default 12 hours On Off Privacy privacy mode will remain on until the user turns it off To turn privacy...

Page 18: ...to 70 seconds default 40 seconds There s an option in programming to extend the conversation time until the end of the lock release period 8 06 TELEPHONE CONNECTIONS Each telephone must be individuall...

Page 19: ...are set via the Jumper pins on the PCB inside the video phone 9 02 RING TONE VOLUME Move the 3 position slide switch on the top left hand side of the video phone to select low medium or high volume r...

Page 20: ...l reference and function is listed in the table below Also see the wiring diagram ZV508I ZV516I sheet 1 9 08 PICTURE ADJUSTMENT Use a blunt instrument such as a ball point pen to press the 3 hidden bu...

Page 21: ...tra Distribution Node Connect the interface unit terminal to the Distribution Node output port terminal Connect the interface unit terminal to the Distribution Node output port terminal Connect the in...

Page 22: ...ransmission distances up to 1000 metres when used with good quality RG59 coaxial cable Both the 2 4 output models have adjustable gain and high frequency lift controls to fine tune the video signal on...

Page 23: ...12V relay board to automatically select the video signal from the door panel in use Video from door 1 camera passes through the normally closed contacts onto the video distribution bus Video from doo...

Page 24: ...her point on the wiring it must be on the lock terminals 0V DC LOCK ONLY LOCK RELAY NC1 NO1 Diode Type 1N4001 or MOV Type GNR07D330K 12 03 LOCK CONNECTION The lock relay common terminal C1 should be l...

Page 25: ...bove ANTI TAILGATE When the door is opened the lock release time will be reset to help prevent unauthorised visitors entering the building during the same lock release period i e Anti Tailgating The d...

Page 26: ...cover to avoid accidental operation 14 02 EXTERNAL FIREMAN S SWITCH There are a variety of different types of Fireman s Switches available from many different suppliers the exact make and model will...

Page 27: ...DOOR PANEL 15 PAC EASIKEY 250 The Entel Ultra door entry system can be interfaced to a PAC Easikey 250 access control system to allow residents to enter the building using an electronic key An Easikey...

Page 28: ...ller and an Entel Ultra door entry system The Easikey 250 should be programmed for a fail secure lock type Refer to the PAC Easikey 250 user and installation guide for full details 15 03 ALTERNATIVE A...

Page 29: ...13 Set every other weekday starting Monday MO WE FR 14 Set every other weekday starting Tuesday TU TH SA 15 Set 3 consecutive days starting Monday MO TU WE 16 Set 3 consecutive days starting Thursday...

Page 30: ...tec GUI Graphical User Interface software This software is supplied on a USB flash memory stick along with the programming lead When installing the software you will need to contact Tynetec s customer...

Page 31: ...now the Comm Port number the software will find the Comm Port being used and enter it into the box IMPORTANT before proceeding your Laptop needs to be connected to the door panel as described in Secti...

Page 32: ...you may want click on the yellow Attached Notes and Printer Functions button and record some useful details about the site This button is at the bottom of the green Configuration Data area of the scr...

Page 33: ...numbers have all been entered for the first distribution node The DIL switch graphic will change to show how the actual DIL switches on distribution board 2 will need to be set Continue filling in th...

Page 34: ...onal door panels Tynetec P No s ZSD501 to ZSD534 DIAL Step Thru Mode for Dial Functional door panels only Tynetec P No ZSD580 If you set DIAL Step Thru Mode then fill each box with flat numbers in the...

Page 35: ...ed 33 34 35 36 37 38 39 40 41 42 43 44 Refer to Figure 2 3x5 Matrix and enter the flat numbers engraved on the buttons in the relevant boxes on the programming screen Enter Flat numbers here Set Stand...

Page 36: ...MMING EXAMPLE 3 EXAMPLE 4 If you have a functional door panel WITH display and you cannot work out which button is which then another option is to temporarily Set Door Panel Type to Digital and click...

Page 37: ...panel display will show HUNG UP LOCK RELEASE TIME This is the time the door lock will remain released from the resident s telephone The LED indicator on ALL telephones will flash green during the lock...

Page 38: ...annels 1 to 8 on the 8 channel video switcher set with ID 1 These outputs can be used to select the correct entrance panel camera for the door panel in use Door panels with ID s 9 to 16 will activate...

Page 39: ...roduces a delay of 10 seconds before the same panel can be used make another call The door panel will display HOLD during this 10 second count down period visitors waiting at other entrances have the...

Page 40: ...th the programming details for the door panel Remember on multi entrance systems you may have more than one File per site if the door panels are programmed differently PRINT COMMISSIONING SHEETS Click...

Page 41: ...Press the door panel button to call the first flat number Check the flat number displayed is the same as that engraved on the door panel button The telephone in the flat should ring and the display s...

Page 42: ...turn the timeclock to AUTO mode If an access code is programmed press the door panel CALL button and the display will show CODE Enter the access code then press the CALL button followed by the 1 butto...

Page 43: ...n the flat you are calling has been left off the hook TRAN the flat you are calling has their call diverted i e your call is being transferred FLAT LOC BUTTON FAULT the telephone has the lock button s...

Page 44: ...Page 44 Tynetec a business unit of Legrand Electric Ltd Unit 10 Cowley Road Blyth Riverside Business Park Blyth Northumberland NE24 5TF Tel 01670 352 371 Fax 01670 362 807 Email sales tynetec co uk W...

Reviews: