APAX-5000 I/O Series User Manual
90
Pulse/DIR, With Reload, Count Once, DI Gate Enable, Rising Edge, Not Retrig-
gerable
Figure 3.31 shows pulse/direction mode, Ch0_A provides the counting function, one
pulse, one count. Ch0_B provides the clockwise and counter clockwise function.
When the counter0 is enabled, the couner0 starts to count. If the counter value is
overflow or underflow, it will reset to the defined value (e.g. 0x33) but won’t keep
counting. If the DI0 status is rising edge, the counter0 will starts to count but cannot
retriggered. Otherwise, the counter0 will stop counting.
Figure 3.46 Pulse/DIR, With Reload, Count Once, DI Gate Enable, Rising Edge,
Not Retriggerable
0x33
0x32
0x31
Up
Down
0x32
0x33
0x34
………
0xF0
0xF1
Ch0_A
Ch0_B
Counter 0
Value
Counter0
Enable
Counter0
Overflow
DI0
0x33
0x34
0x35
Up
Down
0x34
0x33
0x32
………
0x11
0x10
Ch0_A
Ch0_B
Counter 0
Value
Counter0
Enable
Counter0
Underflow
DI0