AMT-70/AMT-73/AMT-75 Installation and Operation
5.8.3
Scheduling Periodic Commands
The user interface allows for the scheduling of commands at specific short interval of time.
The command
every
is used for this function:
# every [period] [explicit command]
↵
The
[period]
is the time interval used to define the periodic interval used to schedule the command.
The value can be between 2 - 60 seconds. The explicit command is defined as the command and
parameters.
# every 5 rber
=>
every 5 rber
rber
RBER = UNLOCKED
=>
rrber
rber
RBER = UNLOCKED
(CTRL-C)
Command scheduling stopped.
Figure 28: Scheduling monotonic commands
When the command is scheduled, the user interface is not available for scheduling other commands. In
order to stop the command scheduling, the character CTRL-C must be used to terminate the
command.
The format of the input lines are defined as follow;
[Command]
Command to be executed
[Comment line]
Start with “#”; all remaining characters are ignored.
[Space line]
Ignored
5.9 Configuring the RS-485 Port
The RS-485 management port is on modem back panel at location P7 (AMT-70) or J13 (AMT-73L) cal
setup of this port is configured using the CLI command set below;
Figure 2 : CLI Command Set for RS-485.
9
87
Command
Description
mcadd [addr]
Sets the M&C address of the RS485 port in client mode.
The range of valid addresses for is 000-255 for any protocol.
The address <000> means the RS-485 port is a non-addressable.
The addresses <001-255> must uniquely be set for each modem connected to the RS-485 bus.
Leading zeros are not required when entering the address.
mccontrol [option]
MCCONTROL [ COMMAND | PACKET | NONE ]
The parameters are described in
Error! Reference source not found.
mcspeed [value]
Set the port speed; Valid values are 4800, 9600, 19200, 28800, 38400, 57600, 115200.
mcparity [parity]
Sets the port parity; the values are ODD, EVEN, NONE