Temperature Control Units : Sentra with VE Series Instrument
Page: 50
Advantage Engineering, Inc.
525 East Stop 18 Road Greenwood, Indiana 46142
317-887-0729 Fax: 317-881-1277
Service Department Fax: 317-885-8683
www.AdvantageEngineering.com
5.8 CELSIUS TEMPERATURE DISPLAY
A.
The following procedure changes the Temperature
display units from Fahrenheit to Celsius. Fahrenheit
display is standard.
B.
Note that there is no indication for Fahrenheit or Celsius
temperature display.
C.
To change to Celsius temperature display, do the
following:
1.
Disengage process operations and relieve all
system pressure.
2.
Disengage main power supply. Verify the Power
light on the display is “off”. Follow standard lock
out procedures.
3.
Remove the thermoformed front panel and set
aside. The panel is attached to the stainless
steel cabinet by 4 small screws.
4.
Open the hinged electrical cabinet panel cover.
The panel is opened by removing four small
screws.
5.
Locate the instrument. A jumper bar controls the
Temperature display. The jumper bar is located
on the larger circuit board.
6.
Using non conductive pliers, remove the jumper
from the Fahrenheit position (standard) to the
Celsius position.
7.
After securing the electrical panel cover and
replacing the thermoformed front panel, resume
operations. The change will take effect once
power is resupplied to the unit.
Jumper location.
Changing jumper bar.
Jumper position for Celsius tem-
perature display.
Summary of Contents for Sentra SK Series
Page 2: ......
Page 6: ...Page 6 THIS PAGE INTENTIONALLY BLANK ...
Page 20: ...Page 20 THIS PAGE INTENTIONALLY BLANK ...
Page 30: ...Page 30 THIS PAGE INTENTIONALLY BLANK ...
Page 36: ...Page 36 THIS PAGE INTENTIONALLY BLANK ...
Page 68: ...Page 68 THIS PAGE INTENTIONALLY BLANK ...
Page 69: ...END 2017 ADVANTAGE ENGINEERING INC RE 01272017 ...
Page 70: ......