8. Test the light in TEST MODE
a. Press TEST radio button
b. Set Pulse Width slider to 1000
c. Set current to 10
d. Press PROGRAM
The light should flash at 10Hz with no external trigger applied.
At this point the attached light head(s) will be ON. Any further adjustments
can be made at any time using the same procedure as above. Adjusting PW
will change the duration of the output pulse, and adjusting CURRENT will
change the output level of the output pulse. Keep in mind that TEST mode
always produces a 10Hz repetition rate pulse.
The Pulsar 320 can communicate via ETHERNET. For instructions on
this, please refer to the TCP/IP setup guide in Appendix D.
4.0 Operation
The following section details the procedures for operation of the Pulsar 320
Controller and defines its various operating modes.
4.1 Definition of Terms
The following terms are used within this manual and, more generally, in
relation to machine vision illumination.
12
Figure 7: Ready to Program Test Mode